Anesthesia Ventilator equipment EKONGB01
MODEL / EKONGB01It provides the physician with a flexible, simple and easy-to-use ventilator; system contains improved alarm features -- including alarm mute; Safety Good air tightness, high reliability.
- Provide A/C ventilation to the patient in the process of operation or in recovery
- after the operation.
- Applied for adult and pediatric
- Microprocessor controlled ,integrated anesthetic ventilation system
Product Details
Quick Details
It provides the physician with a flexible, simple and easy-to-use ventilator
for closed circuit AND semi-close circuit.
Specifications
Anesthesia Ventilator equipment EKONGB01

It provides the physician with a flexible, simple and easy-to-use ventilator
for closed circuit AND semi-close circuit. All the selected patient parameters
are clearly visible on large, bright LCD displays. The audio-visual alarm
system contains improved alarm features -- including alarm mute.

Best Anesthesia Ventilator equipment EKONGB01 Technique Specifications
Main Features:
Provide A/C ventilation to the patient in the process of operation or in recovery
after the operation.
Applied for adult and pediatric
Microprocessor controlled,integrated anesthetic ventilation system
7 inch TFT display screen
Safety Good air tightness, high reliability
Main specifications:
Electronically controlled, pneumatic driven
Patient spectrum: pediatric to bariatric
Ventilation mode: IPPV, SIMV, MANUAL(BAG)
Tidal volume:Adjustment range 0-1500ml
I:E ratio: 4:1-1:8
Frequency:
Adjustment range: 1-100bpm
Under IPPV and Manual mode: 4~65bpm
Under SIMV: 1-40bpm
Monitoring:
VT, MV, BPM, Paw, FiO 2, PEEP, Respiratory Frequency, I:E ratio, Ppeak
Waveform:
Pressure- time, Flow- time
Power: AC 220V±10%, 50HZ±2%, built-in battery > 2hrs(rechargeable) 12V
Inspiratory time (TI) (at SIMV)
— Adjustment range: 0.2 s ~ 6.0 s (the limit of I:E ratio ≤ 4)
Pressure trigger: - 20 cmH2O ~ + 20 cmH2O
Pressure limit:
Patient airway pressure range: -2KPa~10KPa
Airway pressure monitoring range: 0~10KPa
Safety valve pressure limit: 6Kpa
Alarm: High(low) pressure alarm, High(Low) MV alarm, AC power lost alarm
Technical Specifications
Technical parameters from the currently available product information.
- Ventilation mode
- IPPV, SIMV, MANUAL(BAG)
- Tidal volume
- Adjustment range 0-1500ml
- Adjustment range
- 1-100bpm
- Under IPPV and Manual mode
- 4~65bpm
- Under SIMV
- 1-40bpm
- VT, MV, BPM, Paw, FiO 2 , PEEP, Respiratory Frequency, I
- E ratio, Ppeak
- Power
- AC 220V±10%, 50HZ±2%, built-in battery > 2hrs(rechargeable) 12V
- — Adjustment range
- 0.2 s ~ 6.0 s (the limit of I:E ratio ≤ 4)
- Pressure trigger
- - 20 cmH2O ~ + 20 cmH2O
- Patient airway pressure range
- -2KPa~10KPa
- Airway pressure monitoring range
- 0~10KPa
- Safety valve pressure limit
- 6Kpa
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.