Lab Equipment > Handheld blood analyzer

ATP Fluorescence Rapid Detector - colony counter EKONFD02

MODEL / EKONFD02

digital colony counter; 13, automatically determine the qualified; 14, automatic statistical pass rate.

  • High sensitivity - 5X10-18mol / ATP
  • Speed - conventional culture method 18-24h or more, and ATP only need a dozen seconds.
  • Feasibility - The number of microbes has a clear correlation with the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be obtained indirectly.
  • Maneuverability - Traditional training methods need to be carried out by trained technicians in the laboratory; and the ATP fast cleanliness detection operation is very simple and can be operated by the general staff only by simple training.
PRODUCT OVERVIEW

Product Details

Quick Details

atp cell

atp lab

atp testing

digital colony counter

colony counter principle

fungsi colony counter

quebec colony counter

colony counter app

colony counter in microbiology lab

use of colony counter in microbiology

Specifications

ATP cell: ATP Fluorescence Rapid Detector - colony counter EKONFD02

ATP Product - ATP cell: colony counter EKONFD02 Description:

EKONFD02 ATP Fluorescence Rapid Detector for rapid detection of microorganisms in food and drinking water, rapid detection of tableware cleanliness, food processing equipment, worktops, food and beverage utensils and other disinfection results of rapid detection, medical environment work platform for immediate assessment.

atp cell EKONFD02

The device uses biochemical reaction to detect ATP content. When used, samples are collected with pre-wetted water swabs, and the ATP swab is wetted with buffer, which helps to extract the biological material (ATP) from a dry or moist surface. The swab contains a reagent that cleaves the cell membrane, which releases the intracellular ATP and reacts with the specific enzyme contained in the reagent to produce light. The luminescence value is measured by a fluorescence illuminance meter. The number of microorganisms is proportional to the luminous value.

ATP cell: colony counter EKONFD02 Instrument features:

High sensitivity - 5X10-18mol / ATP

Speed - conventional culture method 18-24h or more, and ATP only need a dozen seconds.

Feasibility - The number of microbes has a clear correlation with the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be obtained indirectly.

Maneuverability - Traditional training methods need to be carried out by trained technicians in the laboratory; and the ATP fast cleanliness detection operation is very simple and can be operated by the general staff only by simple training.

Production of the ATP fluorescence detector was the Ministry of Science and Technology "scientific and technological innovation projects"

atp lab EKONFD02

ATP cell: colony counter EKONFD02 The main parameters:

1, large screen clear LCD display

2, the detection accuracy: 5 × 10-18mol / ATP?

3, detection range: 0 to 9999 RLUs

4, detection time: 15 seconds

5, detection error: ± 5 RLUs

6, the operating temperature range: 5 ℃ to 40 ℃

7, the operating humidity range: 20-85%

8, ATP recovery: 90-110%

9, detection mode: RLU, coliform screening

10,50 user ID settings

11, can set the number of results limit: 250

12,2000 memory storage

13, automatically determine the qualified

14, automatic statistical pass rate

15, built-in self-calibration light source

16, boot 30 seconds self test

17, with RS232 interface (with USB interface), the results can be uploaded to the PC

18, instrument size (W × H × D): 192mm × 87mm × 34mm

19, the use of two standard 5 batteries or rechargeable lithium battery

21, standby state (20 ℃): 6 months

22, Chinese operation manual

23, stable liquid luciferase

24, wetting the integrated collection of swabs

Matching Products: ATP Fluorescence Detection Swab, ATP Sample Collector

atp testing EKONFD02

1, ATP fluorescence detection swab using a dedicated sample collection and response integrated rapid detection device, supporting the use of ATP fluorescence detector.

2, the detection of swabs using the world's leading liquid stabilization reagents, more easy to use, to provide a more accurate, light-emitting signal longer and repeat the better test results.

3, can be stored for a long time cold.

4, can detect dry surface and liquid samples.

5,15 seconds to get the test results.

6, applicable to all kinds of domestic, imported ATP fluorescence tester.

7, the only one independent research and development production of ATP fluorescent swab, the price is only half of imported ATP swab.

8, the results of good reproducibility, high reliability, environmental design.

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

the detection accuracy
5 × 10-18mol / ATP?
detection range
0 to 9999 RLUs
detection time
15 seconds
detection error
± 5 RLUs
the operating temperature range
5 ℃ to 40 ℃
the operating humidity range
20-85%
ATP recovery
90-110%
detection mode
RLU, coliform screening
can set the number of results limit
250
,2000 memory storage
13, automatically determine the qualified
instrument size (W × H × D)
192mm × 87mm × 34mm
, the use of two standard 5 batteries or rechargeable lithium battery
21, standby state (20 ℃): 6 months
Random configuration
ATP fluorescence detector (handheld) host, instrument package, lanyard, battery, PC data cable, data analysis software, Chinese operation manual
Matching Products
ATP Fluorescence Detection Swab, ATP Sample Collector

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us