Breast x ray mammogram screening EKON60

MODEL / EKON60

Breast x ray mammogram screening EKON60. Detector, power box, date line, capture card, etc.

  • Automatic voltage compensation
  • dynamic range 14bit digital output
  • ABS high-strength material High quality Brushless digital motor control high-precision Linear guide track
  • Perfect design with patent protection
PRODUCT OVERVIEW

Product Details

Quick Details

High frequency and high voltage generator

Invert Frequency: >80kHz

nominal output current: 0~120mA

Working range: 20~35kV 10-510mAs

Over-voltage protection, over-current protection,

over-power protection, overheat protection

Automatic voltage compensation

High-voltage interlocking device of filament

Specifications

High frequency and high voltage generator

Invert Frequency: >80kHz

nominal output current: 0~120mA

Working range: 20~35kV 10-510mAs

Over-voltage protection, over-current protection,

over-power protection, overheat protection

Automatic voltage compensation

High-voltage interlocking device of filament

mammogram screening

X-ray tube

Focus: 0.1mm/0.3mm

Target angle: 15o

Anode Material:Molybdenum (Mo)

Port Material:Beryllium (Be)

Anode thermal capacity: 210kJ(300KHU)

Inherent filtration: about 1.0mm Be

Rated tube voltage: 20~35 kV

Rated tube current: 0~120mA

Mammogra phy film post

Motorized C-arm:

Electric lift post

580mm vertical movement

Rotation: +175o~-180o

Breast x ray mammogram screening EKON60 video

Electronic compressor

Max. pressure: 200N

Max. travel: 120mm

SID:650mm

Power supply

single phase AC: 220V±10% 50Hz 6kVA

Specialized flat panel detector for Mammography

Detector, power box, date line, capture card, etc.

effective

coverage of

detector

23x15cm / 29x23cm

Pixel matrix 3072x1944 / 3888x3072

Limit of spatial

resolution

6.0Lp/mm

DQE value 70%

dynamic range 14bit digital output

pixel size 75μm

High voltage

Synchronizer

trigger

BNC

Output Camera Link or Ethernet

Working

condition

10℃-40℃

storage

environment

-10℃-50℃

Housing and movement device

Size: 370x275x125CM

stepless speed regulating range: 0~6CM/s

Movement range: 0.5~2CM

ABS high-strength material High quality Brushless digital motor control high-precision Linear guide track

Perfect design with patent protection

Grid

Size: 24x30cm

grid ratio: 3.5: 1

grid density: 36L/CM

focal distance: 65CM

mammogram procedure

Excellent cutting, Make grid lines and angles with excellent accuracy

Newest aperture technology, have higher transmittivity

DICOM Image acquisition workstation

CPU≥Intel Core Duo 2.60GHz

Hardware≥250G high speed Hardware

memory≥2G

display card≥512MB

19〞high brightness high-contrast LCD, 1280*1024 Pixel

resolution

network interface Worklist

DICOM3.0 transmission

100/1000 Gigabit Ethernet

Standard detector image acquisition workstation

Full field digital mammography

The rotation of the arm

The LCD touch screen on the workstation.

The LCD screen below the X-ray tube.

The control of the arm rotation

1. Adopt specialized mammo flat panel detector digital imaging technology.

2. Full size digital mammo x-ray imaging.

3. Unique adopt all-solid-state high frequency high voltage generator. This

technology has got the PATENT IN THE USA.

4. Mammo image acquisition control workstation, DICOM 3.0.

5. Electric Isocentric rotating U-arm with an unique automatic back to center

function.

6. Optional the third generation imported moving grid.

7. Optional auto/semi-auto/manual, three kind exposure mode.

8. Optional image output device: digital film printer.

Packing Details, totally two wooden cases:

216x69x115cm 150kg/210kg

163x97x83cm 85kg/140kg

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Invert Frequency
>80kHz
nominal output current
0~120mA
Working range
20~35kV 10-510mAs
Focus
0.1mm/0.3mm
Target angle
15o
Anode Material
Molybdenum (Mo)
Port Material
Beryllium (Be)
Anode thermal capacity
210kJ(300KHU)
Inherent filtration
about 1.0mm Be
Rated tube voltage
20~35 kV
Rated tube current
0~120mA
Rotation
+175o~-180o
Max. pressure
200N
Max. travel
120mm
SID
650mm
single phase AC
220V±10% 50Hz 6kVA
Pixel matrix
3072x1944 / 3888x3072
dynamic range
14bit digital output