Lab Equipment > Biochemistry analyzer

Buy Fully Automated Biochemistry Analyzer EKONBA57 from Medsinglong

MODEL / EKONBA57

Random access fully automatic biochemistry analyzer; New concept and more friendly software; Automatic washing station for both sample and reagent probe.

  • Random access fully automatic biochemistry analyzer
  • New concept and more friendly software
  • Automatic washing station for both sample and reagent probe
  • Liquid level detection and collision protection for both sample and reagent probe
PRODUCT OVERVIEW

Product Details

Quick Details

Model:EKONBA57 Analytical System:Fully automatic, Random Access Method:End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank,etc Assay Item:80 assay,ISE mould( K+,Cl-,Ca2+)available onreuqest Throughput:1 Reagent:160 tests/hr,2 Reagent:100 tests/hr,With ISE:12 tests/hr

Specifications

Features of Automated Biochemistry Analyzer EKONBA57:

1.Random access fully automatic biochemistry analyzer 2.New concept and more friendly software 3.Automatic washing station for both sample and reagent probe 4.Liquid level detection and collision protection for both sample and reagent probe 5.Reliable cooling system for reagent chamber 6.Powerful reaction cuvette washing system 7.barcode scanner (optional) 8.Lower waste and pro-environment

Buy Fully Automated Biochemistry Analyzer EKONBA57 from Medsinglong

Technical Specifications:

Model:EKONBA57 Analytical System:Fully automatic, Random Access Method:End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank,etc Assay Item:80 assay,ISE mould( K+,Cl-,Ca2+)available onreuqest Throughput:1 Reagent:160 tests/hr,2 Reagent:100 tests/hr,With ISE:12 tests/hr Test Menu: T.BILI r-GT/GGT CHO Ca APOB-1/B CHE D.BILI ALP/AKP TG CL APOB CREA TP UREA CK P CK-MB Mg ALB CREA LDH C ASO AFU Lactic Acid ALT/GPT UA α-HBDH CO2 FMN LP(a) AST/GOT GLU AMY LDL-C HDL-C CHE LA TBA ADA HS-CRP PA Fe Cu Zn C3 C4 IgG IgM IgA and drug, toxicity, etc.

Buy Fully Automated Biochemistry Analyzer EKONBA57 from Medsinglong

Sample Position:50,Including standard, control and STAT; either serum cup or primary tube available Sample Volume:1~100ul, 0.1ul/step Reagent Position:40(80 optional) Reagent Volume:R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step Reagent/Sample Probe:With liquid level sensor, collision sensor, Teflon coating and automatic washing station Reaction Time:0~999 seconds Cuvette:High quality uv-transmitted plastic cuvette. Quartz glass cuvettes on request. Cuvette Washing:8 channels automatic washing system for reaction cuvettes Probe and Mixer Washing:Independent washing station for each sample/reagent probe and mixer Alarm:Automatic alarm for malfunction (e.g: collision, reagent/sample insufficiency, full waste container, etc)

Calibration:Linear, Non-linear, Multi standard, K factor Sample Dilution/Retest:Sample can be diluted and retested if results are out of range or sample is insufficient.Also with calibrator auto diluting function Wavelength:340-810nm Light Source:Halogen lamp Absorbance Resolution:0.0001A Absorbance Accuracy:±0.0003A(0-2.5A) Carry-over:≤0.1% Quality Control:Levy jennings quality control program at 3 levels Barcode:Optional Printer:Multiple report formats available Test control function:New card report formals available System:Windows XP; Windows 7 Power Supply:220V or 110V, 50~60Hz Dimension:85×72×53(cm) Weight:85kg

Buy Fully Automated Biochemistry Analyzer EKONBA57 from Medsinglong
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Analytical System
Fully automatic, Random Access
Method
End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank,etc
Assay Item
80 assay,ISE mould( K+,Cl-,Ca2+)available onreuqest
Throughput
1 Reagent:160 tests/hr,2 Reagent:100 tests/hr,With ISE:12 tests/hr
Sample Position
50,Including standard, control and STAT; either serum cup or primary tube available
Sample Volume
1~100ul, 0.1ul/step
Reagent Position
40(80 optional)
Reagent Volume
R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
Reagent/Sample Probe
With liquid level sensor, collision sensor, Teflon coating and automatic washing station
Reaction Time
0~999 seconds
Cuvette Washing
8 channels automatic washing system for reaction cuvettes
Probe and Mixer Washing
Independent washing station for each sample/reagent probe and mixer
Alarm
Automatic alarm for malfunction (e.g: collision, reagent/sample insufficiency, full waste container, etc)
Sample Dilution/Retest
Sample can be diluted and retested if results are out of range or sample is insufficient.Also with calibrator auto diluting function
Wavelength
340-810nm
Light Source
Halogen lamp
Absorbance Resolution
0.0001A
Absorbance Accuracy
±0.0003A(0-2.5A)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us