Cost effective Auto-Chemistry Analysers CS-300 for sale | Medsinglong
MODEL / CS-300Cost effective Auto-Chemistry Analysers CS-300 for sale | Medsinglong. Light source 20W/12V halogen lamps.
- Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, realizing supermicro volume detection of reaction solution.
- 60nm polished probe, liquid level detection and collision protection.
- Automatic digital liquid level detection, stable performance, reducing probe surface contamination.
- New design reagent disk, less reagent consumption and more test items.
Product Details
Quick Details
Light source 20W/12V halogen lamps. Monochromator Grating photometer Photo-electron road rear spectrometer Wavelengths 340nm~800nm Detector Photo diode LED array
Specifications
Features of Auto-Chemistry Analyzer CS-300:
1.Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, realizing supermicro volume detection of reaction solution. 2.60nm polished probe, liquid level detection and collision protection. 3.Automatic digital liquid level detection, stable performance, reducing probe surface contamination. 4.New design reagent disk, less reagent consumption and more test items. 5.Multiple function sample disk, original blood tube and multi-specification tubes compatible. 6.LIS interface, supporting remote maintenance. 7.User defined combined batch input of patient information, application to fast setting for special hospital, blood station and physical examination.

Specification of Auto-Chemistry Analyzer CS-300:
1.Overall performance Equipment type: Fully automatic, discrete, STAT priority Throughput: 300T/H for photometry tests only; 450T/H for only ISE tests Test principle: Colorimetry, turbidimetries Analysis method: End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
2.Sample reagent unit Sample reagent position: 115sample positions, including 50 routine sample positions, 20 STAT position, 34 calibration positions, 8 QC positions, 3 detergent positions. Sample cuvettes specification: Standard cup, original blood tube, multi-specification tube available (Φ12~16)mm×(25~100)mm Sample volume: 2μl-35μl,0.1 stepping Reagent volume R1:10μl-350μl,R2:10μl-200μl,1μlstepping Sample reagent probe Liquid level detection and collision protection
3.Reaction unit Reagent probe: with the function of liquid level detection and collision detection Reaction cuvette 120 positions optical plastic cup Total volume of reaction liquid 150μl~450μ, 1μl stepping Reaction temperature: 37 degree Reaction disk constant temperature: circulating water Mixer: Mix immediately after adding reagent Wastewater treatment with the function of concentrated waste liquid level alarming
4.Optical system Light source 20W/12V halogen lamps. Monochromator Grating photometer Photo-electron road rear spectrometer Wavelengths 340nm~800nm Detector Photo diode LED array

5.Calibration and QC Calibration method 1 point linear method, 2 point linear method, multiple point linear method, non-linear method Calibration tracking: Automatic description calibration K-value trends QC method: Real-time QC, daily QC and monthly QC Out of control processing: Alarming for out of control sample, record lost control reason
6.Operating system PC operating system Windows XP Analysis control software Graphical operating software English version Report printing Report formats support the user-defined mode, QC and state information etc. System connection TCP/IP network connection, standard RS-232C
7.Others Volume 1060mm×790mm×1150mm Weight 230kg Power supply Voltage AC 220V-22V, 50/60Hz, power 1.5kVA
Technical Specifications
Technical parameters from the currently available product information.
- Equipment type
- Fully automatic, discrete, STAT priority
- Throughput
- 300T/H for photometry tests only; 450T/H for only ISE tests
- Analysis method
- End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
- Sample reagent position
- 115sample positions, including 50 routine sample positions, 20 STAT position, 34 calibration positions, 8 QC positions, 3 detergent positions.
- Sample cuvettes specification
- Standard cup, original blood tube, multi-specification tube available (Φ12~16)mm×(25~100)mm
- Sample volume
- 2μl-35μl,0.1 stepping
- Reagent volume R1
- 10μl-350μl,R2:10μl-200μl,1μlstepping
- Reagent probe
- with the function of liquid level detection and collision detection
- Reaction temperature
- 37 degree
- Reaction disk constant temperature
- circulating water
- Mixer
- Mix immediately after adding reagent
- Calibration tracking
- Automatic description calibration K-value trends
- Out of control processing
- Alarming for out of control sample, record lost control reason
- Power supply Voltage AC
- 220V-22V, 50/60Hz, power 1.5kVA
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.