Cost effective portable Diabetes Insulin Infusion Pump EKONIS32
MODEL / EKONIS32Insulin pump is a portable device which delivers a specific amount of insulin in the body at specific time interval.
- Insulin pump is a portable device which delivers a specific amount of insulin in the body at specific time interval.
- CPU: dual CPU
- Store condition: pls store it in ventilated rooms without any corrosive gases, temperature is from -20℃~55℃, Relative humidity no more than 80%.
- IP grade: IPX8
Product Details
Quick Details
Insulin pump is a portable device which delivers a specific amount of insulin in the body at specific time interval.
Specifications
1. Size: 79*52*20mm 2. Weight: 58g 3. Basal rate segment: 24/48 segments for optional. 4. Infusion frequency: 0--60 times/hour 5. Minimal dose: 0.05u (1u means 0.01ml) 6. Infusion type: basal rate, Temporary basal rate, Bolus, Square wave bolus. 7. Basal rate setting range: 0--5u 8. Basal rate infusion error range: +-5% 9. Temporary basal rate setting range: speed: 0--200%, time: 0--24 hours. 10. Bolus setting range: normally 0--40u, max setting range: 0--85u

11. Bolus infusion error range: +-3% 12. Bolus modes: normal bolus, bolus before 3 meals. 13. Square wave bolus setting range: normally 2--40u, max setting range: 2--85u, time:0--240 minutes. 14. Max daily dose: 200u 15. Screw rewind: motor drive rewind automatically 16. Alarm: ring 17. Alarm situation: A: Meal alarm: 30 minutes after bolus infusion B: Low-Voltage alarm: voltage lower than 1.2v C: No liquid alarm: liquid less than 20u. D: No infusion alarm: no liquid left. E: Liquid blocking alarm: blocking before 6u

18. CPU: dual CPU 19. Reservoir volume: 320u 20. Infusion tube interface: luer interface 21. Battery type: 1*AAA battery 22. Using condition: Temperature: +5℃~+40℃, Relative humidity: 20%~90%, Atmospheric pressure: 700hPa~1060hPa. 23. Store condition: pls store it in ventilated rooms without any corrosive gases, temperature is from -20℃~55℃, Relative humidity no more than 80%. 24. IP grade: IPX8
Technical Specifications
Technical parameters from the currently available product information.
- Basal rate segment
- 24/48 segments for optional.
- Infusion frequency
- 0--60 times/hour
- Minimal dose
- 0.05u (1u means 0.01ml)
- Infusion type
- basal rate, Temporary basal rate, Bolus, Square wave bolus.
- Basal rate setting range
- 0--5u
- Basal rate infusion error range
- +-5%
- Temporary basal rate setting range
- speed: 0--200%, time: 0--24 hours.
- Bolus setting range
- normally 0--40u, max setting range: 0--85u
- Bolus infusion error range
- +-3%
- Bolus modes
- normal bolus, bolus before 3 meals.
- Square wave bolus setting range
- normally 2--40u, max setting range: 2--85u, time:0--240 minutes.
- Max daily dose
- 200u
- Screw rewind
- motor drive rewind automatically
- B: Low-Voltage alarm: voltage lower than
- 1.2v
- Reservoir volume
- 320u
- Infusion tube interface
- luer interface
- Battery type
- 1*AAA battery
- Using condition
- Temperature: +5℃~+40℃, Relative humidity: 20%~90%, Atmospheric pressure: 700hPa~1060hPa.