MODEL / EKONRFB

6 Operating frequency ≥100kHz; 7 Tube current range; 8 Tube voltage range:.

  • 6 Operating frequency ≥100kHz
  • 7 Tube current range
  • 8 Tube voltage range:
  • 7 Anode heat capacity:212kJ(300kHU)
PRODUCT OVERVIEW

Product Details

Quick Details

Radiography & Fluoroscopy

Power voltage: AC380V±38V

Specifications

Digital R&F X-ray machine-EKONRFB

R&F X ray machine-EKONRFB
X ray machine-EKONRFB

MSL R&F X ray machine-EKONRFB Technical

MSL Hot X-ray accessories for sale:

Mass production Mobile X-ray machine 3KW 50mA- EKONPX08

Digital R&F X-ray machine-EKONRFB

Full body radiation protective suit | Radiation proof suit - EKONLS01

Digital R&F X-ray machine-EKONRFB

X-ray lead gloves | Nuclear gloves - EKONRS04

Digital R&F X-ray machine-EKONRFB
Digital R&F X-ray machine-EKONRFB

Discount Medical x-ray film with CE for sale - EKONMF01

Digital R&F X-ray machine-EKONRFB

Green sensitive x ray film with CE for sale - EKONMF02

Digital R&F X-ray machine-EKONRFB

X ray lead glass | X ray protection glass - EKONLG01

Digital R&F X-ray machine-EKONRFB

Lead foil sheet or rolled lead sheet - EKONLS02

Digital R&F X-ray machine-EKONRFB

Lead leg pads | X ray foot guard - EKONRS02

Digital R&F X-ray machine-EKONRFB

Cheap X-ray lead glasses for sale - EKONLG02

Digital R&F X-ray machine-EKONRFB

Hospital or medical rubber sheet - EKONLR01

Digital R&F X-ray machine-EKONRFB

4 Casters X-ray lead screen - EKONLD02

Digital R&F X-ray machine-EKONRFB

Developing solution | Film developing liquid - EKONDS01

Digital R&F X-ray machine-EKONRFB

X-ray intensifying screen - EKONMF04

Digital R&F X-ray machine-EKONRFB

X ray lead protective aprons-EKONLA04

Digital R&F X-ray machine-EKONRFB

X-ray film cassette - EKONMF03

MSL TEAM picture

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

No.Technical parameters
1X-ray generators
1.1Radiography & Fluoroscopy
1.2Power voltage: AC380V±38V
1.3Supply frequency: 50Hz/60Hz±1Hz
1.4Power: 50kW
1.5Max output power: 50kW
1.6Operating frequency ≥100kHz
1.7Tube current range
Radiography:10mA~630mA
Fluoroscopy:0.2mA~5.0mA
1.8Tube voltage range:
Radiography:40~150kV, adjust lenght 1kV
Fluoroscopy:40~125kV, adjust lenght 1kV
1.9Range of exposure duration:0.002s~6.3s (2ms~6300ms)
1.1current time:0.1mAs~630mAs
2Operations Console
2.1Dimension :1400mm×400mm×115mm
3X-ray Pipe sleeve
3.1Max tube voltage:150kV
3.2Thermal capacity:930 kJ(1300kHU)
3.3Inherent filtration:0.7mm AL/75kV
4X-ray tube
4.1Max tube voltage: 150 kV
4.2Max Filament current: 5.3A (Big) /5.4A (small)
4.3Bifocal:0.6mm(small focus)/1.2mm(big focus)
4.4Anode rated power:32KW(small focus);77KW(big focus)
4.5Target angle:12°
4.6Anode rotation speed:2850 rotate/minute
4.7Anode heat capacity:212kJ(300kHU)
5Beam limiter
5.1power supply: 24VAC 4.5A
5.2Inherent filtration:1.0mmAL/70kV
5.3Additional filtration:0/0.5/1.0/1.5mmAL/70kV(Switch inside the machine)
6Diagnostic bed power control cabinet
7Photography bed
7.1voltage:SimplexAC220V±22V
7.2Power frequency:50Hz±1 Hz
7.3input power:≤1kVA
7.4Panel bed size:Length × width × height=2100×775×635mm
7.5Bed mobile performance:Bed lateral movement range: ≥250mm
Bed longitudinal movement range: ≥900mm
8X-ray tube assembly
8.1Maximum tube voltage:150kV
8.2Heat capacity:1100kJ(1540kHU)
8.3Inherent filtration:1.0mm Al
8.4Total filtration:2.5mm AL
9X-ray tube
9.1Operating voltage: 40~150kV
9.2The maximum filament current: 5.5A
9.3Bifocal:1.0mm(Small focus)/2.0mm(Big focus)
9.4Anode input power:30KW(Small focus);50KW(Big focus)
9.5Target surface angle:17..5°
9.6Anode rotation speed:2800 rev / min
9.7Anode heat capacity:140kJ(190kHU)
10Beam limiter
10.1power supply: 24VAC 4.5A
10.2Inherent filtration:1.0mmAL/70kV
10.3Additional filtration: 0/0.5/1.0/1.5mmAL/70kV ( switches inside the machine)
11Vertical type racks
11.1Vertical stroke:the distance between the top edge of film magazine and the ground should not be longer than 800mm, the stroke should no less than 1000mm
11.2Film size:the maximum cassette should not be bigger than 35.6cm×43.2cm
11.3aluminium base grid) convergence distance f0=180cm, grid ratio r=10, grid density N=40lines/cm
12Remote controlled diagnostic bed
12.1Supply voltage:single phase AC220V±22V
12.2Supply frequency: 50Hz±1 Hz
12.3Input power: ≤1kVA
12.4Bed panel dimension: 2000×750×835mm
12.5Bed surface horizontal movement range: 240mm±10mm
12.6Slewing area of the lathe body: 90°~ 0°~ -15°
13Image processor
13.1Power supply: AC100~240V 50Hz
13.2Rated power: 15W
14Monochrome monitor
14.1Power supply: AC100~240V 50-60Hz 0.5A