Surgery

Earthquake Resistance portable Auto CPR machine EKONHS02

MODEL / EKONHS02

In place of mechanical CPR, mechanical CPR devices can automatically deliver CPR strokes to continue blood circulation and oxygen supply of unresponsive victims. A large scale trial revealed one such automatic CPR device, called the AutoPulse, increased the survival rate of patients in need of CPR by 3.6%.

  • 11、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual
  • 12、Electricity, according to the low voltage alarm, start the suspended function
  • 14、Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007
PRODUCT OVERVIEW

Product Details

Quick Details

In place of mechanical CPR, mechanical CPR devices can automatically deliver CPR strokes to continue blood circulation and oxygen supply of unresponsive victims. A large scale trial revealed one such automatic CPR device, called the AutoPulse, increased the survival rate of patients in need of CPR by 3.6%.

Specifications

1、Pressing depth:30 ㎜~65 ㎜ adjustable,one type:5 ㎜,error:±2 ㎜; 2、Pressing release rate:1:1 ; 3、pressure relief valve:0.65Mpa;error:±0.12Mpa; 4、Pressure of gas road is no less than 1Mpa; 5、 Ventilation quanity:500ML no adjust,error:±10%; working pressure:≤816.4N ;

Earthquake Resistance portable Auto CPR machine EKONHS02

6、input power(DC):≤17W; AC:≤54W; 7、Press the ventilation ratio:30:2 continuously adjustable;,error:±1 time; 8、Pressing frequency: 100times/ min,110times/ min,120times/ min error:±1 time; 9、The fastness of fastening band fastness is not less than 100N; 10、The thickness range of patients was 155 to 305MM. 11、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual recovery after air pressure recovery must be deep. 12、Electricity, according to the low voltage alarm, start the suspended function;

Earthquake Resistance portable Auto CPR machine EKONHS02

13、Default mode:Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min Ventilation quanity 500ML 14、Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007, electromagnetic compatibility standard YY05052012; 15、Earthquake Resistance 16、drop resistance 17、The enclosure protection level is IP55 (dustproof and water spray); 18、noise≤70dB ; 19、Working environment : a)Temperature:-20℃~55℃; b)Relative temperatur:10%~90%; c)Atmospheric pressure:500hPa~1060hPa.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

、Pressing depth
30 ㎜~65 ㎜ adjustable,one type:5 ㎜,error:±2 ㎜;
、Pressing release rate
1:1 ;
、pressure relief valve
0.65Mpa;error:±0.12Mpa;
、 Ventilation quanity
500ML no adjust,error:±10%;
working pressure
≤816.4N ;
、input power(DC)
≤17W; AC:≤54W;
、Press the ventilation ratio
30:2 continuously adjustable;,error:±1 time;
、Pressing frequency
100times/ min,110times/ min,120times/ min error:±1 time
、The thickness range of patients was
155 to 305MM.
、Default mode
Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min
、Working environment
a)Temperature:-20℃~55℃;
b)Relative temperatur
10%~90%
c)Atmospheric pressure
500hPa~1060hPa.

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us