EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.

  • Real-time online monitoring running status of sample tray, reagent tray and cuvette
  • Real-time online monitoring reagents residual volume
  • Real-time online monitoring waste volume
  • A revolutionary automatic Chemistry analyzer with
PRODUCT OVERVIEW

Product Details

Quick Details

-Real-time online monitoring running status of sample tray, reagent tray and cuvette

-Real-time online monitoring reagents residual volume

- Real-time online monitoring waste volume

Specifications

EKONBA30 Automatic Chemistry Analyzer High Reputation for Clinic

automated analyzer

EKONBA30 Automatic Chemistry Analyzer Introduction:

-Real-time online monitoring running status of sample tray, reagent tray and cuvette

-Real-time online monitoring reagents residual volume

- Real-time online monitoring waste volume

automatic biochemistry analyzer

A revolutionary automatic Chemistry analyzer with

· Compact design: 54.8cmX42.2cmX38.3cm

· Easy to carry: net weight ≤23kg

-Sample volume: 1.6-50µl, 0.1µl step -Analysis Method: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents

-Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100

-Reagent Position: 26 pcs (Refrigerated function is optional )

-Reagent Volume: 10-500µl, 0.5µl step

Reaction System

- Reaction Cuvette: 60 reusable plastic units

- Optical Length of Cuvette: 6mm

- Reaction Volume: 180~400µl

-Max reaction Time: 10 minutes

- Reaction Temperature: 37±0.1℃

Optical System

- Light Source: halogen-tungsten lamp

- Wavelength: 340-690nm, 9 wavelengths, precision ±1.5nm

- Absorbance Range: 0~5.0Abs

- Resolution: 0.0001Abs

- Rear spectrophotometry

Calibration

-Calibration: linear/nonlinear multi-points calibration

-Re-test: retest the sample automatically when the result is out of the linearity range or the sample is not sufficient

Working Condition

- Power Supply: ~100-240V, 50/60Hz, 300VA

- Temperature: 10-35℃

- Humidity: ≤90%, no dew

Operation System

- Windows XP or Windows 7

Input and Output

- Input: RS-232 interface/computer

-Output: multi-format printout

Op timal substitution of semi-auto Chemistry

analyzer

· Minimal labor required

· Independent mixing probe

· Utility of reagents decreased: 300ul/test

· Efficiency speed: 200 tests/hour

· User friendly: Smart and easy-operating software

· High Accuracy: Minimal operating /random errors

· High reputation for Clinic

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

· Compact design
54.8cmX42.2cmX38.3cm
· Easy to carry
net weight ≤23kg
Sample volume
1.6-50µl, 0.1µl step -Analysis Method: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents
Sample Dilution
automatic/Manual pre-dilution, with dilution ratio up to 1:100
Reagent Position
26 pcs (Refrigerated function is optional )
Reagent Volume
10-500µl, 0.5µl step
Reaction Cuvette
60 reusable plastic units
Optical Length of Cuvette
6mm
Reaction Volume
180~400µl
Max reaction Time
10 minutes
Reaction Temperature
37±0.1℃
Light Source
halogen-tungsten lamp
Wavelength
340-690nm, 9 wavelengths, precision ±1.5nm
Absorbance Range
0~5.0Abs
Resolution
0.0001Abs
Re-test
retest the sample automatically when the result is out of the linearity range or the sample is not sufficient
Power Supply
~100-240V, 50/60Hz, 300VA
Temperature
10-35℃

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.