
EKONBI15 Infant incubator | baby incubator
MODEL / EKONBI15">37℃" temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, SpO 2 , Neonate Bilirubin Phototherapy Equipment which is EKONHD02 (Fixed model), Disposable skin temperature Sensor.
- Set temperature, Air temperature, Baby temperature are displayed separately
- Inclination of bassinet is adjustable
- Multiple failure alarm indications
- RS-232 connector for data output
Product Details
Quick Details
Brief Introduction
● Two control modes: Air mode and Baby mode controlled by micro-computer;
● Set temperature, Air temperature, Baby temperature are displayed separately;
● Passive humidification;
● Inclination of bassinet is adjustable;
● Multiple failure alarm indications;
● RS-232 connector for data output;
● Oxygen input interface;
● Low noise DC motor
Specifications
EKONBI15 Infant incubator | baby incubator
Brief Introduction
● Two control modes: Air mode and Baby mode controlled by micro-computer;
● Set temperature, Air temperature, Baby temperature are displayed separately;
● Passive humidification;
● Inclination of bassinet is adjustable;
● Multiple failure alarm indications;
● RS-232 connector for data output;
● Oxygen input interface;
● Low noise DC motor

EKONBI15 Infant incubator | baby incubator
Specification
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Control Modes: Air mode and Baby mode controlled by micro-computer
Control range of air temperature: 25℃-37℃(override mode: 37℃-39℃ is optional)
Control range of baby temperature: 34℃-37℃(override mode: 37℃-38℃ is optional)
Accuracy of skin temperature sensor: ±0.2℃
The temperature fluctuation range between incubator temperature and average incubator temperature (Under stable temperature condition): ≤0.5℃
Uniformity of temperature: ≤0.8℃ (mattress is on the horizontal position)
Inclination of the bassinet: ±12°
Noise inside hood: ≤45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
The average value of total irradiance for bilirubin Ebi max of photo-therapy equipment:≥640μW/cm 2 (EKONHD01)≥1300μW/cm 2 (EKONHD02)
Built-in timer range: 0~9999 hrs 59min
Accuracy of weight display: ±1% (equipped weighing system)
EKONBI15 Infant incubator | baby incubator
Optional Configuration
">37℃" temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, SpO 2, Neonate Bilirubin Phototherapy Equipment which is EKONHD02 (Fixed model), Disposable skin temperature Sensor.
Environmental temperature
Environment temperature: 20℃~30℃(Set temperature should be 3℃ higher than the environment temperature)
Ambient air velocity: < 0.3m/s
MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Two control modes
- Air mode and Baby mode controlled by micro-computer
- Power requirement
- AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
- Control Modes
- Air mode and Baby mode controlled by micro-computer
- Control range of air temperature
- 25℃-37℃(override mode: 37℃-39℃ is optional)
- Control range of baby temperature
- 34℃-37℃(override mode: 37℃-38℃ is optional)
- Accuracy of skin temperature sensor
- ±0.2℃
- Uniformity of temperature
- ≤0.8℃ (mattress is on the horizontal position)
- Inclination of the bassinet
- ±12°
- Noise inside hood
- ≤45dB(A)
- Failure alarm
- over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
- Built-in timer range
- 0~9999 hrs 59min
- Accuracy of weight display
- ±1% (equipped weighing system)
- Environment temperature
- 20℃~30℃(Set temperature should be 3℃ higher than the environment temperature)
- Ambient air velocity
- < 0.3m/s
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.
