Incubators & Isolettes > Baby incubator

EKONBI17 Infant incubator | neonatal incubator

MODEL / EKONBI17

EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.

  • Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance
  • Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately
  • Multiple failure alarm indications
  • ">37℃" temperature set function as optional configuration
PRODUCT OVERVIEW

Product Details

Quick Details

Brief Introduction

● Two temperature control modes: Air mode and Baby mode controlled by micro-computer;

● Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;

● Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;

● Multiple failure alarm indications;

● ">37℃" temperature set function as optional configuration;

● Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;

● Passive humidification;

● The height of whole unit can be adjusted;

● Oxygen supply system;

● Observation lamp.

Specifications

EKONBI17 Infant incubator | neonatal incubator

Brief Introduction

● Two temperature control modes: Air mode and Baby mode controlled by micro-computer;

● Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;

● Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;

● Multiple failure alarm indications;

● ">37℃" temperature set function as optional configuration;

● Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;

● Passive humidification;

● The height of whole unit can be adjusted;

● Oxygen supply system;

● Observation lamp.

baby incubator

EKONBI17 Infant incubator | neonatal incubator

Specification

AC power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA

DC Power requirement: DC12V/10A or DC24V/6A

Control Mode: Air mode and Baby mode controlled by micro-computer

Air temperature control range: 25℃-37℃ (Override mode 37℃-38℃)

Baby temperature control range: 34℃-37℃ (Override mode 37-37.5℃)

Skin temperature sensor accuracy: ±0.2℃

The temperature fluctuation range between incubator temper-ature and average incubator temperature (under stable temper-ature condition): ≤1.0℃

Temperature uniformity: ≤1.5℃ (mattress is on the horizontal position)

Noise inside hood: ≤52 dB(A)

Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.

Battery continuous working time: 90min (Set temperature is 36℃—

Ambient temperature is 15℃)

EKONBI17 Infant incubator | neonatal incubator

Optional Configuration

">37℃" override temperature mode, Disposable skin temperature sensor, Ambulance trolley

Environmental temperature

Operating range: 10℃~30℃(Set temperature should be 3℃ higher than the environment temperature)

Ambient air velocity: >0.3 m/s,<1.0m/s

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Two temperature control modes
Air mode and Baby mode controlled by micro-computer
Use AC Power and DC Power alternatively, DC
12V or DC 24V Power on the ambulance
AC power requirement
AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA
DC Power requirement
DC12V/10A or DC24V/6A
Control Mode
Air mode and Baby mode controlled by micro-computer
Air temperature control range
25℃-37℃ (Override mode 37℃-38℃)
Baby temperature control range
34℃-37℃ (Override mode 37-37.5℃)
Skin temperature sensor accuracy
±0.2℃
Temperature uniformity
≤1.5℃ (mattress is on the horizontal position)
Noise inside hood
≤52 dB(A)
Failure alarm
over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.
Battery continuous working time
90min (Set temperature is 36℃—
Operating range
10℃~30℃(Set temperature should be 3℃ higher than the environment temperature)
Ambient air velocity
>0.3 m/s,<1.0m/s

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.