Other

EKONBI19 Infant Radiant Warmer | Medical Equipment

MODEL / EKONBI19

EKONBI19 Infant Radiant Warmer | Medical Equipment. Disposable skin temperature sensor and SpO 2 are optional.

  • Set Temperature and Baby Temperature can be displayed separately
  • Horizontal angle of warmer module and inclination of the bassinet can be adjusted
  • The panels surrounded bassinet can be turned outward or disassembled
  • X-ray cassette under the bassinet
PRODUCT OVERVIEW

Product Details

Quick Details

Brief Introduction

● Three control Modes: Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer;

● Set Temperature and Baby Temperature can be displayed separately;

● Horizontal angle of warmer module and inclination of the bassinet can be adjusted;

● The panels surrounded bassinet can be turned outward or disassembled;

● X-ray cassette under the bassinet;

● APGAR timer;

● Multiple failure alarm indications;

● RS232 connector for data output;

● Disposable skin temperature sensor and SpO 2 are optional.

Specifications

EKONBI19 Infant Radiant Warmer | Medical Equipment

Brief Introduction

● Three control Modes: Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer;

● Set Temperature and Baby Temperature can be displayed separately;

● Horizontal angle of warmer module and inclination of the bassinet can be adjusted;

● The panels surrounded bassinet can be turned outward or disassembled;

● X-ray cassette under the bassinet;

● APGAR timer;

● Multiple failure alarm indications;

● RS232 connector for data output;

● Disposable skin temperature sensor and SpO 2 are optional.

baby warmer

EKONBI19 Infant Radiant Warmer | Medical Equipment

Specification

Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA

Control Mode: Pre-warm Mode, Manual Mode and Baby Mode are controlled by micro-computer

Baby Mode temperature control range: 34.5-37.5℃

Temperature sensor display range: 5℃-65℃

Accuracy of skin temperature sensor: ±0.2℃

Temperature uniformity of mattress: ≤2℃

Angle of heater head: 0°-90°any angel for two ways

Inclination of the bassinet: three tilt position

APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′

Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on

EKONBI19 Infant Radiant Warmer | Medical Equipment

Standard Configuration

Main body (including the warmer module, bassinet, main column, mobile stand and temperature controller), I.V. Pole and tray

Environmental Requirement

Operating range: 18℃~30℃

Ambient air velocity rate: <0.3m/s

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Three control Modes
Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer
Disposable skin temperature sensor and SpO
2 are optional.
Power requirement
AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA
Control Mode
Pre-warm Mode, Manual Mode and Baby Mode are controlled by micro-computer
Baby Mode temperature control range
34.5-37.5℃
Temperature sensor display range
5℃-65℃
Accuracy of skin temperature sensor
±0.2℃
Temperature uniformity of mattress
≤2℃
Angle of heater head
0°-90°any angel for two ways
APGAR timer
audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′
Failure alarm
over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on
Operating range
18℃~30℃
Ambient air velocity rate
<0.3m/s

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.