MODEL / EKONBI19EKONBI19 Infant Radiant Warmer | Medical Equipment. Disposable skin temperature sensor and SpO 2 are optional.
- Set Temperature and Baby Temperature can be displayed separately
- Horizontal angle of warmer module and inclination of the bassinet can be adjusted
- The panels surrounded bassinet can be turned outward or disassembled
- X-ray cassette under the bassinet
Product Details
Quick Details
Brief Introduction
● Three control Modes: Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer;
● Set Temperature and Baby Temperature can be displayed separately;
● Horizontal angle of warmer module and inclination of the bassinet can be adjusted;
● The panels surrounded bassinet can be turned outward or disassembled;
● X-ray cassette under the bassinet;
● APGAR timer;
● Multiple failure alarm indications;
● RS232 connector for data output;
● Disposable skin temperature sensor and SpO 2 are optional.
Specifications
EKONBI19 Infant Radiant Warmer | Medical Equipment
Brief Introduction
● Three control Modes: Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer;
● Set Temperature and Baby Temperature can be displayed separately;
● Horizontal angle of warmer module and inclination of the bassinet can be adjusted;
● The panels surrounded bassinet can be turned outward or disassembled;
● X-ray cassette under the bassinet;
● APGAR timer;
● Multiple failure alarm indications;
● RS232 connector for data output;
● Disposable skin temperature sensor and SpO 2 are optional.

EKONBI19 Infant Radiant Warmer | Medical Equipment
Specification
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA
Control Mode: Pre-warm Mode, Manual Mode and Baby Mode are controlled by micro-computer
Baby Mode temperature control range: 34.5-37.5℃
Temperature sensor display range: 5℃-65℃
Accuracy of skin temperature sensor: ±0.2℃
Temperature uniformity of mattress: ≤2℃
Angle of heater head: 0°-90°any angel for two ways
Inclination of the bassinet: three tilt position
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on
EKONBI19 Infant Radiant Warmer | Medical Equipment
Standard Configuration
Main body (including the warmer module, bassinet, main column, mobile stand and temperature controller), I.V. Pole and tray
Environmental Requirement
Operating range: 18℃~30℃
Ambient air velocity rate: <0.3m/s
MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Three control Modes
- Pre-warm Mode, Manual Mode and Baby Mode control by micro-computer
- Disposable skin temperature sensor and SpO
- 2 are optional.
- Power requirement
- AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA
- Control Mode
- Pre-warm Mode, Manual Mode and Baby Mode are controlled by micro-computer
- Baby Mode temperature control range
- 34.5-37.5℃
- Temperature sensor display range
- 5℃-65℃
- Accuracy of skin temperature sensor
- ±0.2℃
- Temperature uniformity of mattress
- ≤2℃
- Angle of heater head
- 0°-90°any angel for two ways
- APGAR timer
- audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′
- Failure alarm
- over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on
- Operating range
- 18℃~30℃
- Ambient air velocity rate
- <0.3m/s