EKONZX01 Automatic Tourniquet System | Medical Equipment manufacturer
MODEL / EKONZX01Aluminum shell with an qualified hardware. Core components made in TAIWAN Simple operation system includes leaking inspection. Allow pressure change during surgeries. Automatic sound alarm prevents accident.
- EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.
Product Details
Quick Details
Technical Parameter:
Pressure Set: 0~70kpa (525mmHg)
Pressure Stability Precision: +/-1kpa
Time Set: 0~120min
Initial Inflate Time: ≤10s
Performance:
Aluminum shell with an qualified hardware. Core components made in TAIWAN Simple operation system includes leaking inspection. Allow pressure change during surgeries. Automatic sound alarm prevents accident.
Specifications
EKONZX01 Automatic Tourniquet System | Medical Equipment manufacturer
Technical Parameter:
Pressure Set: 0~70kpa (525mmHg)
Pressure Stability Precision: +/-1kpa
Time Set: 0~120min
Initial Inflate Time: ≤10s
Performance:
Aluminum shell with an qualified hardware. Core components made in TAIWAN Simple operation system includes leaking inspection. Allow pressure change during surgeries. Automatic sound alarm prevents accident.

EKONZX01 Automatic Tourniquet System | Medical Equipment manufacturer
Protect Function:
Deflate slowly, alarms when pressure gets over 80kpa.
Power Function:
Remains pressure value when power cut off
Alarm function:
Sound alarm at 10min 5min 1min before the surgery ends.
Inflation and Deflation:
Fast inflation in 10 seconds. Deflates slowly as 3kpa per second to avoid accident.
Timer: Timer counts working pressure value full surgery time and surgery time remaining.
Memory Function: Memorize the working pressure from last surgery saves time for set up.
EKONZX01 Automatic Tourniquet System | Medical Equipment manufacturer
MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Pressure Set
- 0~70kpa (525mmHg)
- Pressure Stability Precision
- +/-1kpa
- Time Set
- 0~120min
- Initial Inflate Time
- ≤10s
- Deflate slowly, alarms when pressure gets over
- 80kpa.
- Timer
- Timer counts working pressure value full surgery time and surgery time remaining.
- Memory Function
- Memorize the working pressure from last surgery saves time for set up.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.