Surgery

Full Automatic Endoscope Irrigation Pump EKONGY01

MODEL / EKONGY01

Endoscope Irrigation Pump EKONGY01 is suitable for Arthroscopy, Hysteroscopy and Urology systems etc.

  • Outstanding flow pressure sensor, high sensitivity, very safe and stable
  • Used in orthopaedics,Gynecology and Urology systems.
  • Use roller pump to get large flow,irrigation tube can be autoclavable sterilization to avoid secondary pollution.
  • Sterile tubing sets with sensor,a peristaltic pump,with two channels.
PRODUCT OVERVIEW

Product Details

Quick Details

Endoscope Irrigation Pump EKONGY01 is suitable for Arthroscopy, Hysteroscopy and Urology systems etc.

Pressure presetting range: 15-600mmHg(2-80kPa)

Flow rate: 0.1-1.0l/min

Sterile tubing sets with sensor, a peristaltic pump,with two channels

Emulsion tube and shim are replaceable (5pcs, L: approx.16cm)

Outstanding flow pressure sensor, high sensitivity, very safe and stable

Specifications

Full Automatic Endoscope Irrigation Pump EKONGY01

Endoscope Irrigation Pump EKONGY01 is suitable for Arthroscopy, Hysteroscopy and Urology systems etc.

Pressure presetting range: 15-600mmHg(2-80kPa)

Flow rate: 0.1-1.0l/min

Sterile tubing sets with sensor, a peristaltic pump,with two channels

Emulsion tube and shim are replaceable (5pcs, L: approx.16cm)

Outstanding flow pressure sensor, high sensitivity, very safe and stable

irrigation medical

Full Automatic Endoscope Irrigation Pump EKONGY01

Main Characteristic:

1. Used in orthopaedics,Gynecology and Urology systems.

1. Use roller pump to get large flow,irrigation tube can be autoclavable sterilization to avoid secondary pollution.

2. Sterile tubing sets with sensor,a peristaltic pump,with two channels.

3. Emulsion tube and shim are replaceable(5pce,L:approx.16cm).

4. High sensitivity pressure sensor.

5. Pressure is adjustable on request and real time monitored.

irrigation medical

Full Automatic Endoscope Irrigation Pump EKONGY01

Technical parameters:

Full Automatic Endoscope Irrigation Pump EKONGY01

TECHNICAL DATA

Power source: AC110\220V±10%50/60HZ 0.5A

Fuses: φ5×20mm250V 2A

Max.power consumption: 100W

Pressure presetting range: 15-600mmHg(2-80kPa,error approx.+2kPa)

Flow rate: 0.1-1.0l/min (error approx.+20%)

Signal/Noise ratio: ≤55dB

Safety standard: IEC601-1

Storage temp.: -15℃ to +50℃

Operating temp.: 0℃ to 45℃

Relative humidity:30% to 85%

N.W.: 8kg

Dims: 385x385x120mm

STANDARD FEATURES

Main unit

·Sterile tubing sets with sensor

·Shims of sensor (3pcs), emulsion tube and shim (5pcs, L: approx.16cm)

·Power cable

irrigation medical

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Supply voltage~220V 50Hz
Power150VA
Range of press15~400mmHg(2~53.3kPa)
Range of flw0.1~1.0L/min
Noise≤70dB

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us