High Frequency X-ray Radiolography System EKONHX02 for sale
MODEL / EKONHX02Table side human graphic color LCD touch screen for parameters setting ,together with; the remote control exposure method make the operating much safer and convenient; Adopt technology of kV closed-loop control and mAs digital closed-loop control to.
- Table side human graphic color LCD touch screen for parameters setting ,together with
- the remote control exposure method make the operating much safer and convenient .
- Adopt technology of kV closed-loop control and mAs digital closed-loop control to
- ensure the accuracy and reproducibility of the x-ray dose.
Product Details
Quick Details
Item:EKONHX02 Power Output:25kW Tube Voltage:40~125kV Tube Current:200mA Inverter Frequency:40kHz Power supply:380V,50Hz,Capacity≥40kVA mAs:0.4-360mAs Dual focus Small focus: 0.6;Large focus: 1.3 Thermal capacity:900kJ(1200kHU) The speed of the rotary anode:3000rpm Grid: Table Photography:103L /inch 15"x18" Bucky Stand Photography:103L /inch 18"x18"
Specifications
High Frequency X-ray Radiography System EKONHX02:
Table side adjustment, Remote-control Exposure Excellent X-ray Source, Low skin dose 1.Table side human graphic color LCD touch screen for parameters setting,together with the remote control exposure method make the operating much safer and convenient. 2.Adopt technology of kV closed-loop control and mAs digital closed-loop control to ensure the accuracy and reproducibility of the x-ray dose. 3.High frequency high voltage x-ray generator and high frequency inverter power make excellent X-ray source, low skin dose and sharp image.

Features:
1.Multi body parts, multi position photography parameters for adult and children have been preprogrammed. Easy to learn and operate even to new operators 2.The compact design of the Xx-ray monoblock make it much easier to install. 3.Self-protection and faultcode alarming function for much safer operate. 4.The table can float freely, electromagnetic brake to make the photography position more accuracy. 5.Standard: Bucky Stand: used for the vertical photography of head, chest, pelvis, limbs and so on. 6.Standard: human graphical LCD touch screen control console makes compartment photography be possible.

Technical Parameters:
Item:EKONHX02 Power Output:25kW Tube Voltage:40~125kV Tube Current:200mA Inverter Frequency:40kHz Power supply:380V,50Hz,Capacity≥40kVA mAs:0.4-360mAs Dual focus Small focus: 0.6;Large focus: 1.3 Thermal capacity:900kJ(1200kHU) The speed of the rotary anode:3000rpm Grid: Table Photography:103L /inch 15"x18" Bucky Stand Photography:103L /inch 18"x18"

Technical Specifications
Technical parameters from the currently available product information.
- Power Output
- 25kW
- Tube Voltage
- 40~125kV
- Tube Current
- 200mA
- Inverter Frequency
- 40kHz
- Power supply
- 380V,50Hz,Capacity≥40kVA
- mAs
- 0.4-360mAs
- Dual focus Small focus
- 0.6;Large focus: 1.3
- Thermal capacity
- 900kJ(1200kHU)
- The speed of the rotary anode
- 3000rpm
- Table Photography
- 103L /inch 15"x18"
- Bucky Stand Photography
- 103L /inch 18"x18"
- Standard
- human graphical LCD touch screen control console makes compartment photography be possible.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.