High Frequency X-ray Radiolography System EKONHX07 for sale | Medsinglong
MODEL / EKONHX07AEC: No AEC; Designed with many beneficial characteristics to improve workflow; Table side human graphic LCD touch screen for parameters setting and remote control, makes it easy and safe to operate.
- AEC: No AEC
- Designed with many beneficial characteristics to improve workflow.
- Table side human graphic LCD touch screen for parameters setting and remote control, makes it easy and safe to operate.
- Self—protection and fault—code alarming function for much safer operate .
Product Details
Quick Details
1.Power Output:55KW 2.Inverter Frequency:≧60KHz 3.Tube Voltage:40KV~150KV 4.Tube Current For digital Radiography:10-500mA 5.mAs: 0.1mAs~630mAs 6.Focus (Rotary Anode): 0.6/1.2mm 7.Anode Heat Content:210kJ 8.Sleeve Heat Content:900kJ 9.Anode Speed:9700rpm 10.AEC: No AEC 11.Photography Bed
Specifications
Features of High Frequency X ray Radiography System EKONHX07:
Designed with many beneficial characteristics to improve workflow. AEC(automatic exposure control)enables auto selection of radiographic factors,save time,eliminates retakes,increases diagnostic capability and lowers the radiation dose. APR(anatomical programme)with film density control in which exposure factors include kV and mAs are automatically selected depending upon the physique of the patient and part of the body to be radiographed. Table side human graphic LCD touch screen for parameters setting and remote control, makes it easy and safe to operate. Self—protection and fault—code alarming function for much safer operate.

Specification of High Frequency X ray Radiography System EKONHX07:
1.Power Output:55KW 2.Inverter Frequency:≧60KHz 3.Tube Voltage:40KV~150KV 4.Tube Current For digital Radiography:10-500mA 5.mAs: 0.1mAs~630mAs 6.Focus (Rotary Anode): 0.6/1.2mm 7.Anode Heat Content:210kJ 8.Sleeve Heat Content:900kJ 9.Anode Speed:9700rpm 10.AEC: No AEC 11.Photography Bed

*Length:2000mm *Width:760mm *Height:≤700mm *Longitudinal remove range:≥900mm *Transverse remove range:≥220mm *Cassette film size:14''*17'' *Cassette longitudinal range:≥560mm
12.Panel Detector:CSI, 14*17,150μm,14bits,3.4lp/mm 13.Workstation:CPU i3, 8G+1TB, 24inches LCD,1920*1200 14.Arm Movement:
*SID: 450mm~1200mm *X ray tube assembly longitudinal movement range along bed: ≥1370mm *X ray tube assembly can rotate around its axis≥±90° *X ray tube assemble can rotate around its axis≥35° *X ray tube assemble can rotate around column axis: 4*90°

15.Weight:
1#Main machine, X ray tube, operator station and bucky stand: NW: 685kgs GW: 880kgs 2#Electrical cabinet and High pressure tank: NW: 200kgs GW: 360kgs


Technical Specifications
Technical parameters from the currently available product information.
- Power Output
- 55KW
- Inverter Frequency
- ≧60KHz
- Tube Voltage
- 40KV~150KV
- Tube Current For digital Radiography
- 10-500mA
- mAs
- 0.1mAs~630mAs
- Focus (Rotary Anode)
- 0.6/1.2mm
- Anode Heat Content
- 210kJ
- Sleeve Heat Content
- 900kJ
- Anode Speed
- 9700rpm
- *Length
- 2000mm
- *Width
- 760mm
- *Height
- ≤700mm
- *Longitudinal remove range
- ≥900mm
- *Transverse remove range
- ≥220mm
- *Cassette film size
- 14''*17''
- *Cassette longitudinal range
- ≥560mm
- Panel Detector
- CSI, 14*17,150μm,14bits,3.4lp/mm
- Workstation
- CPU i3, 8G+1TB, 24inches LCD,1920*1200
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.