Surgery

High quality Oscillator EKON-OS02

MODEL / EKON-OS02

The product is mainly used for blending of the syphilis test card, colloid reaction and complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.

  • complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.
  • the function indication lights is on and the relative parameters are shown on instrument.
  • Press the “Timing” key (the correspondent indication light is on). Adjust the set-values
  • The instrument is bumming for alarm after timing is finished, while the time shows “00:00”.
PRODUCT OVERVIEW

Product Details

Quick Details

The product is mainly used for blending of the syphilis test card, colloid reaction and complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.

Specifications

High quality Oscillator EKON-OS02

MSL High quality Oscillator EKON-OS02

MSL High quality Oscillator EKON-OS02 Profile

The product is mainly used for blending of the syphilis test card, colloid reaction and

complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.

The product is stable, reliable and operator friendly, which is a requisite instrument for

tests in all kinds of hospitals, institutions, centers of prevention and cure of STD,

sanitation and anti-epidemic stations, blood stations.

Technical Parameters

Voltage: AC 220V 50/60Hz

Power: 15W

Rotation Speed: 0-210 r/min. adjustable

Timing: 0-24 hours adjustable,count down mode

“0” is normally running mode

Over-center Rotation Diameter: 22mm

Dimension of Working Table: 384×248(mm)

Fuse: 2A

Oscillator

Operation

1.When it is connected to the power and is switched on, we hear the bumming sound,

the function indication lights is on and the relative parameters are shown on instrument.

2.Press the “Rotation Speed” key (the correspondent

indication light is on). Adjust the “Rotate” key, “10 Rotates” key or “100 Rotates” key to

adjust the set-value. After finish these, press the “Enter” Key to store the set-value.

If adjustment is unnecessary, skip this step. (Note: The adjust range of “Rotate” key

is 0-9,“10 Rotates” key is 0-4 while “100 Rotates” key is 0-2 ).

3. Press the “Timing” key (the correspondent indication light is on). Adjust the set-values

by “Minute” key and “10 Minutes” key as well as “Hour” key. After finishing this, press the

“Enter” key to store the set-value. If adjustment is unnecessary, skip this step. (Note:

The adjust range of “Minute” key is 0-9, “10 Minutes” key is 0-5 while “Hour” key is 0-23).

4.After set the parameters, press “Start/Pause” key to start the instrument. You may press the

“Start/Pause” key again to pause the instrument while the timing is also stops. When start again,

timing continues. It can be done repeatedly. You can check all the parameters by pressing

different keys during machine running, but the values can’t be adjusted. After pause the instrument,

the value can be adjusted. The instrument returns to timing indication mode after 60 seconds stop.

5.The instrument is bumming for alarm after timing is finished, while the time shows “00:00”.

You may press the “Start/Pause” key directly to start the instrument if the value adjustment is

unnecessary. The instrument shows the set-value if paused for more than 60 seconds.

6. Turn off the instrument when the operation is finished.

Oscillator
Oscillator
New Medical equipment Oscillator
Best Medical equipment Oscillator
Cheap Medical equipment Oscillator

Precautions

1.AC power should be well connected to the ground and its voltage should be within the regulated scope.

2. The instrument should be put on a proper place on the working station. Avoid heavy press.

3. Avoid long time unloaded running and cut off the power when it is not in use.

4. Never open the shell to avoid electric shock. Find special person for maintenance.

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in Oscillator. Please feel free to

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Voltage
AC 220V 50/60Hz
Power
15W
Rotation Speed
0-210 r/min. adjustable
Timing
0-24 hours adjustable,count down mode
Over-center Rotation Diameter
22mm
Dimension of Working Table
384×248(mm)
Fuse
2A

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us