Lab Equipment > Biochemistry analyzer

Laboratory Automatic Chemistry Analyzer machine System URIT-8021A

MODEL / URIT-8021A

Laboratory Automatic Chemistry Analyzer machine System URIT-8021A. Principle: Photoelectric colorimetry

  • new factor automatically
  • Support bi-direction LIS and HIS interface
  • Durable ceramic syringes to ensure accuracy & precision
  • High accurate optical system
PRODUCT OVERVIEW

Product Details

Quick Details

Assay methods: End Point, Kinetic, Fix time etc.

Principle: Photoelectric colorimetry

Light Source: Halogen lamp 12V/20W

Photometry range: 0~3.2Abs

Resolution: 0.0001Abs

Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm

Throughput: 200 tests/hour

Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)

Specifications

24 hour non-stop cooling Chemistry Analyzer machine URIT-8021A

Random access, 200 tests per hour

Durable ceramic syringes

Select best test point by reaction curve, create

new factor automatically

Support bi-direction LIS and HIS interface

Automatic-Chemistry-Analyzer-machine-URIT-8021A

Durable ceramic syringes Chemistry Analyzer machine URIT-8021A Features

24 hour non-stop cooling system to ensure reagent at 2-8℃

Durable ceramic syringes to ensure accuracy & precision

High accurate optical system

Collision protection in both vertical and horizontal directions, stop & alarm automatically

once touching barrier, not affect former tests

Automatic eligible cuvettes detection & selection

Select best test point by reaction curve, create new factor automatically

Support LIS interface

Automatic-Chemistry-Analyzer-machine-URIT-8021A-1

Automatic eligible cuvettes detection Chemistry Analyzer machine URIT-8021A Specifications

Assay methods: End Point, Kinetic, Fix time etc.

Principle: Photoelectric colorimetry

Light Source: Halogen lamp 12V/20W

Photometry range: 0~3.2Abs

Resolution: 0.0001Abs

Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm

Throughput: 200 tests/hour

Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)

Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions

Reaction tray: 120 reaction cuvettes

Sample volume: 2~100ul, with 0.1ul increment

Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment

Minimum reaction volume: 180uL

Maximum reaction time: 10 minutes

Water Consumption: Less than 5L/hour under working status

Clean unit: 8-step auto-washing system with detergent

Calibration: Calibration reset, select best test point by reaction curve, no need second calibration

Line/non-line;multi-standards assay

Control rules: Westgard multi-rule, Cumulative sum check, Twin plot

3 level controls for each ifem, analyxing and printing QC analysis diagram

Temperature control: incubator 37±0.1℃

Power supply: AC 230(1±10%)V, 50/60Hz, 500VA

Ambient: Operating temperature: 10~30℃

Relative humidity: ≤85%

Atmospheric pressure: 86~106kPa

Automatic-Chemistry-Analyzer-machine-URIT-8021A-2

High performance mixer design

Absence of cross contamination

Optimal homogenization in minimum time

Mixing immediately after dispensing of sample and the second reagent

Automatic-Chemistry-Analyzer-machine-URIT-8021A-3

Stable Optical System

High accurate, close, static state optical system

Spot photometry with high speed digital transmission system

Durable cuvettes

8-step auto-washing system with detergent and deion-water to ensure

cuvettes clean and decrease cross contamination

120 reaction cuvettes located in a constant temperature incubator

Low consumption, open reagent design

Automatic-Chemistry-Analyzer-machine-URIT-8021A-4
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Assay methods
End Point, Kinetic, Fix time etc.
Light Source
Halogen lamp 12V/20W
Photometry range
0~3.2Abs
Resolution
0.0001Abs
Wavelength
340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
Throughput
200 tests/hour
Reagent tray
60 reagent positions (include1detergent position,1 dilution position)
Sample tray
71 sample positions, including detergent, standard, QC, STAT positions
Reaction tray
120 reaction cuvettes
Sample volume
2~100ul, with 0.1ul increment
Reagent volume
R1:10~500uL, R2: 10~500uL,with 0.5uL increment
Minimum reaction volume
180uL
Maximum reaction time
10 minutes
Water Consumption
Less than 5L/hour under working status
Clean unit
8-step auto-washing system with detergent
Temperature control
incubator 37±0.1℃
Power supply
AC 230(1±10%)V, 50/60Hz, 500VA
Ambient
Operating temperature: 10~30℃

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?