Anesthesia machine > Ventilator Machine

Medical ventilator equipment EKONVM13 for sale

MODEL / EKONVM13

EKONVM13 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates time and capacity switches and pressure restrictions.

  • EKONVM12 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates
  • patients who are in a deadly danger with respiratory support at their most dangerous stage; protect patients
  • injury to maintain the patients’ breathing function; provide breathing support for patients after sickness or
  • conveniently and accurately.
PRODUCT OVERVIEW

Product Details

Quick Details

EKONVM13 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates time and capacity switches and pressure restrictions.

Specifications

Medical ventilator equipment EKONVM13 for sale

ventilator price | ventilator machine price

MSL ventilator equipment VM13

Medical ventilator equipment EKONVM13 Main Characteristics

EKONVM12 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates

time and capacity switches and pressure restrictions. The main purposes of ventilator are to: provide the

patients who are in a deadly danger with respiratory support at their most dangerous stage; protect patients

in going through their dangerous period; ensure a successful basic treatment for further recovery; provide

substitutes for anti-reversion respiratory muscle pathological changes or anti-reversion upper windpipe

injury to maintain the patients’ breathing function; provide breathing support for patients after sickness or

during the recovery period after operation.

Medical ventilator equipment VM13

Main characteristics are stated as follows:

a.Gas-driven, electrical control, time-pressure switch, and pressure limit control

b.Have air-oxygen mixer particles of high-performance, can adjust the oxygen concentration

conveniently and accurately.

c.Apply electronic PEEP, can make continuous adjustment of PEEP.

d.PTR has 2 kinds of trigger ways: Pressure trigger and flow trigger.

e. Apply highly and fast sensitive pressure sensor and flow sensor to airway pressure, gas flow

detection, control and display, and has ventilation auto-compensation

f. Many ventilator modes: VCV, PCV. PSV, SIMV. PSIMV(SIMV+PSV), CPAP.

g. Apply led, real-time displays these parameters, such as controlling frequency, tidal volume,

ventilation, total breathing frequency, self respiratory rate, compliance, airway resistance,

oxygen concentration, it also displays pressure and curve of flow vale to time.

h. P-V (Pressure-Volume), F-V (Flow-Volume).

i. When the ventilator runs abnormally or is incorrectly operated, it will trigger both audio

and visual alarms to protect itself.

j. even if the power is off, no chokes will occur to the patients, for the respiration tubes are

connected to the outer atmosphere.

advanced Anesthesia Ventilator

MSL Medical ventilator equipment EKONVM13 for sale Work Environment

Normal working conditions of PA-900B II:

_____Temperature: 10~40℃

_____Relative Humidity: ≤80%

_____Atmospheric Pressure: 86 kPa ~ 106 kPa

_____Gas: medical oxygen and compressed air of 280~ 600kPa

_____Power: AC220V±10%, 50±1Hz, 40VA, with ground protection.

MSL New Anesthesia Ventilator for sale

Cheap Medical ventilator equipment EKONVM13 for sale Structure and work principle

•EKONVM12 ventilator is motivated by medical oxygen and compressed air. Under inspiratory phase,

two ways of compressed gases (compressed oxygen and air) enter air-oxygen commingler, forming a

gas mixtureof certain pressure that mixes medical oxygen, and then enter electronic controlled inspirator

rates valve of high performance, last do mechanical ventilation in the patient’s respiration tract through

inhale tubes of ventilator; under expiratory phase, the patients exhale gas to the atmosphere through filter,

and expiration control valve of the expiration tubes. During this process, high-performance rates control

valve, highly sensitive flow sensor and pressure sensor and single-chip microcomputer control system

are adopted to bring airway pressure, airway flow speed closed-loop regulation, thus realize Gas-driven,

electrical control, time-pressure switch, and pressure limit control

NOTICE:This unit could work properly under the condition of medical oxygen and compressed air

combining together. Meanwhile, the pressure for the common gas should be the around 0.4MPa.

The ventilator will do real-time display of these following parameters:

_____Work mode and I/E ratio

_____ Pre-set controlling frequency

_____Tidal volume per respiration

_____The appearance of spontaneous respiration and its frequency

_____ Oxygen concentrator

_____ Plat form pressure and Airway peak pressure

_____ Compliance and airway resistance

_____Real-time changes of airway internal pressure

_____Display of Inspiratory status and Expiratory status, actual respiratory frequency

_____Ventilation capacity per minute

_____ Airway pressure, respiratory frequency, tidal volume, alarm bounds of Ventilation capacity per minute.

The ventilator triggers alarms whenever abnormal situation occurs. For example, the ventilator will trigger

alarms when airway pressure is too low which may be caused by leakage or falling off. When the airway

pressure is too high which may be caused by the blockage of tubes, it will not only trigger alarms automatically,

but also transfer the ventilator from inspiratory status to expiratory status to release the over-high pressure if

the pressure keeps on rising.

New Anesthesia Ventilator

Best Medical ventilator equipment EKONVM13 for sale Technical Specification

Basic functions

_____Assistant Respiration, controlling respiration, autonomous respiration

_____ End-Inspiratory Halts

_____ PEEP

_____Sigh (deep breath)

_____ Standby

Work Mode

_____VCV (volume control ventilation)

_____PCV (Pressure Control Respiration mode)

_____PSV (Pressure supporting volume)

_____ IMV (Intermittent Mandatory Ventilation mode)

_____SIMV (Simultaneous Intermittent Mandatory mode)

_____CPAP (Continuous Positive Airway Pressure)

Basic Parameters

Tidal Volume adjustment: 0-1500ml

Tidal Volume: 50~1500ml, error of displayed value: 100 ml and lower than ±20 mL, others ±20 %

Maximum ventilation capacity per minute: ≥18L/m,

Oxygen Concentration: 21%-100%,±15% error allowed

Ventilation Conformance: ≤ 30 mL/kPa

IPPV range: 0~99 times/m, ±15% error allowed.

I/E Ratio: 4:1、3:1.、2:1.、1:1.、1:1.5、1:2.、1:2.5、1:3.、1:4, ±15% error allowed

SIMV: 1-20 times/m, ±15% error allowed.

Maximum Safety Pressure: ≤6.0kPa

Control Pressure: 0.3kPa ~ 4 – PEEP

PTR sensitivity: PEEP-1 cmH2O~PEEP—9 cmH2O adjustable, ±1 cmH2O error allowed.

End-inhale continuous time: 0 ~ 50% adjustable, that is 0.1s ~ 20 s.

PEEP: 0.1 kPa~1.0 kPa

flow trigger sensitivity: Level 3 and Level 8.

Pressure Restriction: 1~6kPa, ±20 % error allowed.

Sigh( deep breath): deep breath in 100 times breath, 1-8 times adjustable( after 10-100 times’ control breath,

there will be 1 time deep breath), the inspiration time is 1.5 times to the setup time.

Sustained Operation: 24 hours for main power supply, no less than 30 minutes for built-in battery application only.

Anesthesia Ventilator for sale
MSL New Anesthesia Ventilator
MSL New Anesthesia Ventilator for sale
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

f. Many ventilator modes
VCV, PCV. PSV, SIMV. PSIMV(SIMV+PSV), CPAP.
_____Temperature
10~40℃
_____Relative Humidity
≤80%
_____Atmospheric Pressure
86 kPa ~ 106 kPa
_____Gas
medical oxygen and compressed air of 280~ 600kPa
_____Power
AC220V±10%, 50±1Hz, 40VA, with ground protection.
NOTICE
This unit could work properly under the condition of medical oxygen and compressed air
Tidal Volume adjustment
0-1500ml
Tidal Volume
50~1500ml, error of displayed value: 100 ml and lower than ±20 mL, others ±20 %
Maximum ventilation capacity per minute
≥18L/m
Oxygen Concentration
21%-100%,±15% error allowed
Ventilation Conformance
≤ 30 mL/kPa
IPPV range
0~99 times/m, ±15% error allowed.
I/E Ratio
4:1、3:1.、2:1.、1:1.、1:1.5、1:2.、1:2.5、1:3.、1:4, ±15% error allowed
SIMV
1-20 times/m, ±15% error allowed.
Maximum Safety Pressure
≤6.0kPa
Control Pressure
0.3kPa ~ 4 – PEEP
PTR sensitivity
PEEP-1 cmH2O~PEEP—9 cmH2O adjustable, ±1 cmH2O error allowed.

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.