Other
Medical Waste Incinerator - Solve Medical Waste EKONWI150B
MODEL / EKONWI150BMedical Waste Incinerator - Solve Medical Waste EKONWI150B. Welcome to medicalequipment-EKON.com.
- Combustion-support combustion machines
PRODUCT OVERVIEW
Product Details
Quick Details
Specifications
Medical Waste Incinerator - Solve Medical Waste EKONWI150B

Medical Waste Incinerator - Solve Medical Waste EKONWI150B

S tandard configuration
Medical Waste Incinerator - Solve Medical Waste EKONWI150B




MSL TEAM picture
Welcome to medicalequipment-msl.com.
TECHNICAL DATA
Technical Specifications
Technical parameters from the currently available product information.
| Applicable hospital size (number of beds) | 200-300beds |
| Burning Ability | 100-150kg/ times (daily incineration3-6 times) |
| Size of the Burner | 2m×1.4m×3.5m |
| Applicable hospital size (number of beds) | 200-300beds |
| Burning Ability | 100-150kg/ times (daily incineration3-6 times) |
| Size of the Burner | 2m×1.4m×3.5m |
| Volume of the Burner | Gasification room1.4m³,secondary bumingroom0.7m³,drift a long buming a room0.1m³ |
| Size of the filling entrance | 760mm×960mm |
| Chimney | Height 10m out-radius¢300mm |
| Blower | Power 0.5kw |
| Combustion-support combustion machines | Power 0.11kw,fuelconsumption4-10kg/h |
| Re-burning machine | Power 0.22kw,fuelconsumption10-18kg/h |
| Running voltage | 380V |
| Weight | About 8000kg |
| No | Name | Amount | Specifications | Notes |
| 1 | Incinerator | 1 | A3 steel refractories | Main part |
| 2 | The 2 combustion chamber and the combustion chamber mixed | 1 | A3 steel refractories | Installed in main body |
| 3 | Electric box | 1 | main body | |
| 4 | Fluegas purification system | 1 | A3 steel refractories | Installed in main body |
| 5 | Combustion burner | 1 | BTL-10(Italy) | main body |
| 6 | Reburning burner | 1 | BTL-20G(Italy) | main body |
| 7 | blower | 1 | 750W/220V/380V | main body |
| 8 | Ash rake | 1 | ¢200mm×2500mm | |
| 9 | Pump | 1 | main body | |
| 10 | fuel tank | 1 | main body | |
| 11 | fuel tank bracket | 1 | ¢400mm×2200mm | |
| 12 | Chimney | 2 | ¢300mm×5000mm ¢300mm×2000mm | |
| 13 | Filter switch | 5 | main body | |
| 14 | Thermocouple | 2 | 1200℃ | main body |
| 15 | Operational procedures | 1 | main body |
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.