X rays > x ray mammogram

Navigator Platinum Mammography EKONRX01

MODEL / EKONRX01

EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.

  • d) Support ISO center rotation function
  • g) C-arm: Motorized Movement, Dual side digital display
  • h) Digital Display of C-arm Rotation and thickness on each side of C-arm
  • i) Emergency "OFF" switch for added safety and operator control
PRODUCT OVERVIEW

Product Details

Quick Details

Specifications

Navigator Platinum Mammography EKONRX01

x ray mammography

Navigator Platinum Mammography EKONRX01

x ray mammography

Navigator Platinum Mammography EKONRX01

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

The Mammography System
a) Standalone System (Generator Integrated within the main machine) b) Generator: 100 kHz, 20 kV to 40 kV in 1 kV c) High performance X-ray tube: Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) d) Support ISO center rotation function e) C-arm Rotation range: +180°/-135° f) Height range of breast support surface: 750mm-1330mm(±2%) g) C-arm: Motorized Movement, Dual side digital display h) Compression Paddles: Dual Smart Compression Mechanism i) Spatial Resolution: ≥15Lp/mm j) Film size: 18*24cm k) Focal distance: 650mm l) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminum m) Additional filter Switch: Automatic n) Field adjustment: Auto/Manual o) Magnification ratio: (1.6)/1-(1.8)/1 p) Exposure mode: Manual / AEC/AAEC q) Power supply: single phase, AC 220~230 V±10% r) Frequency: 50/60 Hz±1 Hz s) Max. power: 5000 KW t) N.W.: 240 Kg u) Packing Size: 115 X 85 X 135 CM
The Mammography System
a) Standalone System (Generator Integrated within the main machine) b) Generator: 100 kHz, 20 kV to 40 kV in 1 kV c) High performance X-ray tube: Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) d) Support ISO center rotation function e) C-arm Rotation range: +180°/-135° f) Height range of breast support surface: 750mm-1330mm(±2%) g) C-arm: Motorized Movement, Dual side digital display h) Compression Paddles: Dual Smart Compression Mechanism i) Spatial Resolution: ≥15Lp/mm j) Film size: 18*24cm k) Focal distance: 650mm l) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminum m) Additional filter Switch: Automatic n) Field adjustment: Auto/Manual o) Magnification ratio: (1.6)/1-(1.8)/1 p) Exposure mode: Manual / AEC/AAEC q) Power supply: single phase, AC 220~230 V±10% r) Frequency: 50/60 Hz±1 Hz s) Max. power: 5000 KW t) N.W.: 240 Kg u) Packing Size: 115 X 85 X 135 CM
High Frequency High Voltage Generator
a) Type: single phase, Constant High Frequency Generator b) Working frequency: 100 kHz c) Max. Output:3.5 kW d) kV Range: 20 kV to 40 kV in 1 kV increments e) Tube mA Range: 15mA to 110 mA f) mAs range: 10~600mAs
X-Ray Tube
a) Anode Type: Molybdenum b) Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) c) Fixed Filter: 0.5mm Be d) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminum e) Anode Speed: 3000rmp/min Maxi. Speed:10000rmp/min f) Tube mA Range: 35mA (Small Focal)/140mA (Large Focal) g) Anode heating capacity: 320 KJ/416KHU
C-arm Assembly
a) C-arm Movement: All Motorized b) ISO center rotation: Yes c) Position location: CC,OBL,LAT d) C-arm Rotation range: +180°to -135° e) C-arm travel range: 1385mm~1965mm (±1%) f) Focal distance: 65cm g) 2 side foot switch control h) Digital Display of C-arm Rotation and thickness on each side of C-arm i) Emergency "OFF" switch for added safety and operator control j) Dual Smart Compression Mechanism
Compression Paddles (Smart Paddle System)
a) Digital Display of compression force on each side of C-arm b) Dual Smart Compression Mechanism c) Smart Compression Mechanism: Motorized up and down, soft compress, auto release, manual de-compress d) Paddles Travel Range: 268mm e) Compression Range: 0~196N (20 kg), increment 9.8 N (1 kg)
Power Capacity4000VA
Voltage220V AC Single Phase
Frequency50Hz/60Hz
Ground requirementsLess than 0.6Ω
ItemTemperatureHumidity/Atmosphere
Parameter-40 ℃~+55 ℃≤93%700hPa~1060hPa
ItemTemperatureHumidityAtmosphere
Parameter10℃~40℃20%~80%700hPa~1060hPa

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us