Beauty Equipment

New arrival High Intensity Focused Ultrasound EKONHF02

MODEL / EKONHF02

New arrival High Intensity Focused Ultrasound EKONHF02. Improve chin lines and marionette lines.

  • Improve chin lines and marionette lines.
  • Improve skin and make it lustrous.
  • Mode Pulsed Digital Output Mode
  • Ship the control unit and handle in a container. Ship alone the
PRODUCT OVERVIEW

Product Details

Quick Details

Lift and tighten buccal skin.

Improve chin lines and marionette lines.

Improve skin and make it lustrous.

Remove cervical stripe to protect neck form aging.

Specifications

New arrival High Intensity Focused Ultrasound EKONHF02

advanced New arrival High Intensity Focused Ultrasound EKONHF02

HIFU "High Intensity Focused Ultrasound", named aka Ultra pola

r sonic face-lifts, means that high-energy ultrasound focused toget

her is into the 4.5 mm light muscular neurotic o layer (SMAS). T

he heat energy of HIFU can make the SMAS layer along with the

muscle and skin immediacy tighten to lift face timely. In addition,

the heat energy of HIFU effectively stimulate continuous generati

on of collagen, whose elastin make skin more elastic.

High Intensity Focused Ultrasound EKONHF02

Type HIFU

Frequency 7MHz 4MHz

Mode Pulsed Digital Output Mode

Tips DS7-1.5 DS7-3.0 DS4-4.5

Interval 0.5-5.0mm

Length 5.0~30mm 5.0/Stepping

Input Power AC 110V~220V~50Hz/60Hz

Weight Cart:20kg Host Machine:10kg

Description of Control Units

Project Description

Handle Connection Socket Be used to insert handld head.

USB Port(2) Optional USB(No)

Error Indicator Light Warning with wrong operation

On\Off Button Light on in power-on state.

Light off in power-off state.

USB Port of Rear Panel Acce Key of Ulthera System User(No)

Main Power Switch Power Supply

System(AC220V/50Hz)

Power Socket Be used to insert power cord.

Description of Treatment Handle Events

Events Description

On Button Imaging Start\Stop Treatment\Start Treatment

Play Buttion Indicator on when it works.

Treatment Probe Different treatment probe used in

different target parts of patient.

Soft Glue Sheath of Cable Connect handles with control parts.

Description of Treatment Probe

Events Description

Top Mark Probe transducer and other information

Treatment instructions Length and center mark(center treatment

transducer)of the longest process lines

Sensor Types of Treatment Probe

Types Frequency Treatment Depth Image Depth Scan Length

DS 7-1.5 7MHz 1.5mnm 0-8mm 25mm

DS 7-3.0 7MHz 3.0mm 0-8mm 25mm

DS 4-4.5 4MHz 4.5mm 0-8mm 25mm

cheap MSL New arrival High Intensity Focused Ultrasound EKONHF02
cheap MSL High Intensity Focused Ultrasound EKONHF02
use High Intensity Focused Ultrasound EKONHF02
best MSL New arrival High Intensity Focused Ultrasound EKONHF02
best MSL High Intensity Focused Ultrasound EKONHF02

MSL New arrival High Intensity Focused Ultrasound EKONHF02 Packing:

1. Ship the control unit and handle in a container. Ship alone the

encapsulation of treatment probe from the control unit and hand

les, and transport it in the aseptic bags. Ship the treatment probe

and gel packed separately.

2. The system device could be placed in carts or other workbenc

h with the host and the power cord offered. Carts recommended t

o provide users with a more flexibility and secure treatment. The

weight and size of treatment are included in technical data manu

al.

3.The internal space of host at the back, sides, bottom and top of

the cooling system. The system equipment runs normally with c

ontinuous use for long time.

best High Intensity Focused Ultrasound EKONHF02

High Intensity Focused Ultrasound EKONHF02 therapeutic range

1、 Lift and tighten buccal skin.

2、Improve chin lines and marionette lines.

3、Improve skin and make it lustrous.

4、Remove cervical stripe to protect neck form aging.

5、Improve skin elasticity and the contour.

6、Tighten forehead skin tissue and improve eyebrows lines

7、Eliminate the wrinkles around the brow, eyes and lips.

MSL New arrival High Intensity Focused Ultrasound EKONHF02
MSL High Intensity Focused Ultrasound EKONHF02

Best New arrival High Intensity Focused Ultrasound EKONHF02 Clean Probe and Tips

Due to probe contacted with patient's skin, clean the probe to

please use 70% of propyl alcohol disinfecting skin. Doctor can also

use pure cotton with

70% of standard propyl alcohol to gently wipe the probe and cable.

Both probe and handle all need to be kept clean and dry. After

wiping the probe and put it back for using conveniently next time.

cheap High Intensity Focused Ultrasound EKONHF02

Use New arrival High Intensity Focused Ultrasound EKONHF02 System Maintenance

Follow principles for better working performance.

(1) Check whether probe and connection are in good condition.

(2) Ensure right identity of probe and expand working life of system.

(3) No to put the handle and probe on the floor and other hard panel,

if not, it could cause damages.

(4) No to pull handle cable that could lead to fault of internal wire

and connection.

(5) Use ultrasound gel only and no to use other lubrication and lotion

especially mina oil. If not, it could cause fault of tips and circuit.

(6) Keep a distance between working tips and patients. Strictly

operate as-per the principle.

(7) Clean tips without ultrasound gel after treatment to avoid it

covered on tips and other control parts.

(8) Check whether the packing of new tip is in good condition when

using it.

(9)Probe has a function of memory and keep it away

from things with magcard and static when finishing the

treatment.

(10)No to pull others except probe into handles,

otherwise it will damage safety system.

MSL New arrival High Intensity Focused Ultrasound EKONHF02 for sale

Target user

1. People with wrinkle,Crow's feet, forehead lines and

nasolabial sulcus on face, cervical stripe, striae gravid arum

stretch marks on abdomen and fat grain on thigh and other

wrinkles crowd;

2. Skin aging, skin relaxation, skin prolapse, Jaw loose, do

uble chin, canthus prolapse, eyebrow drooping;

3. Skin loosing, skin bloating, proud flesh on abdomen and

arms, hip Dysplasia, abdominal relaxation after postpartum

flabby and weight loss, lose shape.

MSL High Intensity Focused Ultrasound EKONHF02 for sale

Taboo crowd

1、Pregnant women

2、Patients with severe heart disease, diabetes and hyperthyroidism

3、Cancer patients in advanced stage

4、Patients with unhealed wounds

5、Patients injected Botox in one year

6、Patients with ideal effect of treatment

High Intensity Focused Ultrasound EKONHF02 for sale
use MSL New arrival High Intensity Focused Ultrasound EKONHF02

Safty

1. Carrying Safety

For there are precision instruments in operating system,

please user try not to move the machine over a long distance.

disorder and impact energy output.

2、Electric Safety

This operating system should be used single-phase 220V

for power supply and the maximum output current is not

more than 10A. In order to expand the machine service and

reduce the influence of power fluctuations to machine, user

need to use 1000W of voltage regulator.

3、Operation Safety

Keep your system clean and ensure the condensing agent

with no pollution to system.

4、 Safety Device of System

In order to ensure the safety in use, this product is strictly

enforced (electricity) light enterprise standard Immediately

check whether the circuit is safe and check constantly circuit

in operating process.

What is process of treatment

Ultra ™ is a comfortable therapy without an injection of anesthesia.

When ultrasonic infiltration into the subcutaneous tissue, the patient

will have feeling of warmth and mild needle, which is the way of

tightening and lifting skin for Ultra with a lasting curative effect.

The whole process takes about 60 minutes. You can immediately do

all daily activities after treatment. If making up necessarily, the

skin of patients will be red temporarily, but subside after several

hours.

How many times do i need to be treated?

The effect of treatment will be obvious for most patients

accepted after 1 to 2 times of treatment.. Your doctor will determine

the number of treatment. In addition, The doctor woof Sloane' and

clinic will arrange review for you, take photos and know your

progress after treatment.

Which part could be treated on the face?

Any part on the face could be treated such as forehead, temple,

midrace, the lower face and jaw. In some cases, the neck can also

be treated. It is very popular for treatment with face and neck at

same time, for it can bring the best and the most obvious effect for

patients. During the consultation, The doctor of Sloane and clinic

will customize a set of suitable course for you.

MSL TEAM picture

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Frequency
7MHz 4MHz
Weight Cart
20kg Host Machine:10kg

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us