New arrival High Intensity Focused Ultrasound EKONHF02
MODEL / EKONHF02New arrival High Intensity Focused Ultrasound EKONHF02. Improve chin lines and marionette lines.
- Improve chin lines and marionette lines.
- Improve skin and make it lustrous.
- Mode Pulsed Digital Output Mode
- Ship the control unit and handle in a container. Ship alone the
Product Details
Quick Details
Lift and tighten buccal skin.
Improve chin lines and marionette lines.
Improve skin and make it lustrous.
Remove cervical stripe to protect neck form aging.
Specifications
New arrival High Intensity Focused Ultrasound EKONHF02

HIFU "High Intensity Focused Ultrasound", named aka Ultra pola
r sonic face-lifts, means that high-energy ultrasound focused toget
her is into the 4.5 mm light muscular neurotic o layer (SMAS). T
he heat energy of HIFU can make the SMAS layer along with the
muscle and skin immediacy tighten to lift face timely. In addition,
the heat energy of HIFU effectively stimulate continuous generati
on of collagen, whose elastin make skin more elastic.

Type HIFU
Frequency 7MHz 4MHz
Mode Pulsed Digital Output Mode
Tips DS7-1.5 DS7-3.0 DS4-4.5
Interval 0.5-5.0mm
Length 5.0~30mm 5.0/Stepping
Input Power AC 110V~220V~50Hz/60Hz
Weight Cart:20kg Host Machine:10kg
Description of Control Units
Project Description
Handle Connection Socket Be used to insert handld head.
USB Port(2) Optional USB(No)
Error Indicator Light Warning with wrong operation
On\Off Button Light on in power-on state.
Light off in power-off state.
USB Port of Rear Panel Acce Key of Ulthera System User(No)
Main Power Switch Power Supply
System(AC220V/50Hz)
Power Socket Be used to insert power cord.
Description of Treatment Handle Events
Events Description
On Button Imaging Start\Stop Treatment\Start Treatment
Play Buttion Indicator on when it works.
Treatment Probe Different treatment probe used in
different target parts of patient.
Soft Glue Sheath of Cable Connect handles with control parts.
Description of Treatment Probe
Events Description
Top Mark Probe transducer and other information
Treatment instructions Length and center mark(center treatment
transducer)of the longest process lines
Sensor Types of Treatment Probe
Types Frequency Treatment Depth Image Depth Scan Length
DS 7-1.5 7MHz 1.5mnm 0-8mm 25mm
DS 7-3.0 7MHz 3.0mm 0-8mm 25mm
DS 4-4.5 4MHz 4.5mm 0-8mm 25mm





MSL New arrival High Intensity Focused Ultrasound EKONHF02 Packing:
1. Ship the control unit and handle in a container. Ship alone the
encapsulation of treatment probe from the control unit and hand
les, and transport it in the aseptic bags. Ship the treatment probe
and gel packed separately.
2. The system device could be placed in carts or other workbenc
h with the host and the power cord offered. Carts recommended t
o provide users with a more flexibility and secure treatment. The
weight and size of treatment are included in technical data manu
al.
3.The internal space of host at the back, sides, bottom and top of
the cooling system. The system equipment runs normally with c
ontinuous use for long time.

High Intensity Focused Ultrasound EKONHF02 therapeutic range
1、 Lift and tighten buccal skin.
2、Improve chin lines and marionette lines.
3、Improve skin and make it lustrous.
4、Remove cervical stripe to protect neck form aging.
5、Improve skin elasticity and the contour.
6、Tighten forehead skin tissue and improve eyebrows lines
7、Eliminate the wrinkles around the brow, eyes and lips.


Best New arrival High Intensity Focused Ultrasound EKONHF02 Clean Probe and Tips
Due to probe contacted with patient's skin, clean the probe to
please use 70% of propyl alcohol disinfecting skin. Doctor can also
use pure cotton with
70% of standard propyl alcohol to gently wipe the probe and cable.
Both probe and handle all need to be kept clean and dry. After
wiping the probe and put it back for using conveniently next time.

Use New arrival High Intensity Focused Ultrasound EKONHF02 System Maintenance
Follow principles for better working performance.
(1) Check whether probe and connection are in good condition.
(2) Ensure right identity of probe and expand working life of system.
(3) No to put the handle and probe on the floor and other hard panel,
if not, it could cause damages.
(4) No to pull handle cable that could lead to fault of internal wire
and connection.
(5) Use ultrasound gel only and no to use other lubrication and lotion
especially mina oil. If not, it could cause fault of tips and circuit.
(6) Keep a distance between working tips and patients. Strictly
operate as-per the principle.
(7) Clean tips without ultrasound gel after treatment to avoid it
covered on tips and other control parts.
(8) Check whether the packing of new tip is in good condition when
using it.
(9)Probe has a function of memory and keep it away
from things with magcard and static when finishing the
treatment.
(10)No to pull others except probe into handles,
otherwise it will damage safety system.

Target user
1. People with wrinkle,Crow's feet, forehead lines and
nasolabial sulcus on face, cervical stripe, striae gravid arum
stretch marks on abdomen and fat grain on thigh and other
wrinkles crowd;
2. Skin aging, skin relaxation, skin prolapse, Jaw loose, do
uble chin, canthus prolapse, eyebrow drooping;
3. Skin loosing, skin bloating, proud flesh on abdomen and
arms, hip Dysplasia, abdominal relaxation after postpartum
flabby and weight loss, lose shape.

Taboo crowd
1、Pregnant women
2、Patients with severe heart disease, diabetes and hyperthyroidism
3、Cancer patients in advanced stage
4、Patients with unhealed wounds
5、Patients injected Botox in one year
6、Patients with ideal effect of treatment


Safty
1. Carrying Safety
For there are precision instruments in operating system,
please user try not to move the machine over a long distance.
disorder and impact energy output.
2、Electric Safety
This operating system should be used single-phase 220V
for power supply and the maximum output current is not
more than 10A. In order to expand the machine service and
reduce the influence of power fluctuations to machine, user
need to use 1000W of voltage regulator.
3、Operation Safety
Keep your system clean and ensure the condensing agent
with no pollution to system.
4、 Safety Device of System
In order to ensure the safety in use, this product is strictly
enforced (electricity) light enterprise standard Immediately
check whether the circuit is safe and check constantly circuit
in operating process.
What is process of treatment
Ultra ™ is a comfortable therapy without an injection of anesthesia.
When ultrasonic infiltration into the subcutaneous tissue, the patient
will have feeling of warmth and mild needle, which is the way of
tightening and lifting skin for Ultra with a lasting curative effect.
The whole process takes about 60 minutes. You can immediately do
all daily activities after treatment. If making up necessarily, the
skin of patients will be red temporarily, but subside after several
hours.
How many times do i need to be treated?
The effect of treatment will be obvious for most patients
accepted after 1 to 2 times of treatment.. Your doctor will determine
the number of treatment. In addition, The doctor woof Sloane' and
clinic will arrange review for you, take photos and know your
progress after treatment.
Which part could be treated on the face?
Any part on the face could be treated such as forehead, temple,
midrace, the lower face and jaw. In some cases, the neck can also
be treated. It is very popular for treatment with face and neck at
same time, for it can bring the best and the most obvious effect for
patients. During the consultation, The doctor of Sloane and clinic
will customize a set of suitable course for you.
MSL TEAM picture
Technical Specifications
Technical parameters from the currently available product information.
- Frequency
- 7MHz 4MHz
- Weight Cart
- 20kg Host Machine:10kg
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team