New Biochemistry Automatic Chemistry Analyzer URIT-8210 for sale
MODEL / URIT-8210New Biochemistry Automatic Chemistry Analyzer URIT-8210 for sale. Principle: Photoelectric colorimetry
- 10-wavelength, high accurate and
- Supports LIS system
- High accurate optical system Automatic Chemistry Analyzer URIT-8210 Features
- Dual-unattached durable ceramic syringes to ensure accuracy & precision
Product Details
Quick Details
Assay methods: End Point, Kinetic, Fix time etc.
Principle: Photoelectric colorimetry
Light Source: Halogen lamp 12V/20W
Photometry range: 0~3.2Abs
Resolution: 0.0001Abs
Wavelength: 10 wavelengths optional (340nm~800nm)
Throughput: 330tests/hour
Reagent tray: 59 reagent positions, 1 detergent position
Specifications
Biochemistry Automatic Chemistry Analyzer URIT-8210
Random access, 330 tests/hour
ISE and barcode (Optional)
10-wavelength, high accurate and
closed optical system
Unattached probe and mixer
Supports LIS system

High accurate optical system Automatic Chemistry Analyzer URIT-8210 Features
24 hour non-stop cooling system to ensure reagent at 2-8℃
Dual-unattached durable ceramic syringes to ensure accuracy & precision
Collision protection in both vertical and horizontal directions, stop & alarm automatically
once touching barrier, not affect former tests
Automatic eligible cuvettes detection & selection
Select best test point by reaction curve, create new factor automatically
High accurate optical system
Support LIS interface

High accurate optical system Automatic Chemistry Analyzer URIT-8210 Specifications
Assay methods: End Point, Kinetic, Fix time etc.
Principle: Photoelectric colorimetry
Light Source: Halogen lamp 12V/20W
Photometry range: 0~3.2Abs
Resolution: 0.0001Abs
Wavelength: 10 wavelengths optional (340nm~800nm)
Throughput: 330tests/hour
Reagent tray: 59 reagent positions, 1 detergent position
Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions
Reaction tray: 90 reaction cuvettes
Sample volume: 2~100ul, with 0.1ul increment
Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment
Minimum reaction volume: 150uL
Maximum reaction time: 10 minutes
Water Consumption: 6L/hour under working status
Clean unit: 8-step auto-washing system with detergent and 37℃ water
Calibration: Calibration reset, select best test point by reaction curve, no need second calibration
Line/non-line;multi-standards assay
Control rules: Westgard multi-rule, Cumulative sum check, Twin plot
3 level controls for each ifem,analyxing and printing QC analysis diagram
Temperature control: incubator 37±0.1℃
Power supply: AC110/230(1±10%)V,50/60Hz,500VA
Ambient: Operating temperature: 10~30℃
Relative humidity: ≤85%
Atmospheric pressure: 86~106kPa

High performance mixer design
Absence of cross contamination
Optimal homogenization in minimum time
Mixing immediately after dispensing of sample and the second reagent

Efficient reaction system
Reaction disk: 90 semi-permanent plastic cuvettes
Minimum reaction volume:150 μl
Operating temperature: 37℃, Temperature fluctuation:±0.1℃

Technical Specifications
Technical parameters from the currently available product information.
- Assay methods
- End Point, Kinetic, Fix time etc.
- Light Source
- Halogen lamp 12V/20W
- Photometry range
- 0~3.2Abs
- Resolution
- 0.0001Abs
- Wavelength
- 10 wavelengths optional (340nm~800nm)
- Throughput
- 330tests/hour
- Reagent tray
- 59 reagent positions, 1 detergent position
- Sample tray
- 71 sample positions, including detergent, standard, QC, STAT positions
- Reaction tray
- 90 reaction cuvettes
- Sample volume
- 2~100ul, with 0.1ul increment
- Reagent volume
- R1:10~500uL, R2: 10~500uL,with 0.5uL increment
- Minimum reaction volume
- 150uL
- Maximum reaction time
- 10 minutes
- Water Consumption
- 6L/hour under working status
- Clean unit
- 8-step auto-washing system with detergent and 37℃ water
- Temperature control
- incubator 37±0.1℃
- Power supply
- AC110/230(1±10%)V,50/60Hz,500VA
- Ambient
- Operating temperature: 10~30℃
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team