Other

Percutaneous Jaundice Tester | Jaundice Treatment EKONJM01

MODEL / EKONJM01

. Measurement: light reflective; . LED;Light source: LED; .Can displayed separately mg / dL, μmol / L in the meantime.

  • . Measurement: light reflective
  • . LED;Light source: LED
  • .Can displayed separately mg / dL, μmol / L in the meantime.
  • . Open Preparation time: boot, no need to prepare
PRODUCT OVERVIEW

Product Details

Quick Details

Main requirement:

1). Measurement: light reflective

2). LED;Light source: LED

3). Display: LCD

4). Indication error: 0 ~ 25 mg / dL ± 1.0 mg / dL

5). Power: Lithium battery (DC3.6V, 1000mAh ± 20%), after a fully charged can check Measuring more than 800 times;

6). Check color screen: white end face is 0, the yellow end face 16.0 ± 1.0

neonatal jaundice

jaundice in newborns

bilirubin levels in newborns

Jaundice Tester

Specifications

Percutaneous Jaundice Tester | Jaundice Treatment EKONJM01 Detail:

jaundice treatment

Percutaneous Jaundice Tester | Jaundice Treatment EKONJM01

Main Function

1).Can displayed separately mg / dL, μmol / L in the meantime.

2).Data storage: can storage 200 measuring date.

3).Calculating the average function: It has the function that measuring 2-5 times, then workout the average automatically.

4). Open Preparation time: boot, no need to prepare

5). Battery voltage detection function: it will be displayed “Low Battery” when the battery voltage less than 3.6V.

6). Automatic shutdown after the non-working state, for 10 minutes: automatic shutdown function

7). Battery display: Top right corner of the viewing screen display 、、、、,it respectively means the left battery electric quantity is about 100%、75%、50%、25%、0%。

8). charging display: The viewing screen will be lighten and displayed “Charging...” during charging.

9). charging automatic protection function: It will stop charging automatically at the time battery voltage charging arrive 4.2V±0.05V.

neonatal jaundice

jaundice in newborns

bilirubin levels in newborns

Jaundice Tester

jaundice in newborns

Percutaneous Jaundice Tester | Jaundice Treatment EKONJM01

Main requirement:

1). Measurement: light reflective

2). LED;Light source: LED

3). Display: LCD

4). Indication error: 0 ~ 25 mg / dL ± 1.0 mg / dL

5). Power: Lithium battery (DC3.6V, 1000mAh ± 20%), after a fully charged can check Measuring more than 800 times;

6). Check color screen: white end face is 0, the yellow end face 16.0 ± 1.0

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

. Display
LCD
. Indication error
0 ~ 25 mg / dL ± 1.0 mg / dL
. Power
Lithium battery (DC3.6V, 1000mAh ± 20%), after a fully charged can check Measuring more than 800 times
. Check color screen
white end face is 0, the yellow end face 16.0 ± 1.0
.Data storage
can storage 200 measuring date.
.Calculating the average function
It has the function that measuring 2-5 times, then workout the average automatically.
. Battery voltage detection function
it will be displayed “Low Battery” when the battery voltage less than 3.6V.
. Automatic shutdown after the non-working state, for 10 minutes
automatic shutdown function
. Battery display
Top right corner of the viewing screen display 、、、、,it respectively means the left battery electric quantity is about 100%、75%、50%、25%、0%。
. charging display
The viewing screen will be lighten and displayed “Charging...” during charging.
. charging automatic protection function
It will stop charging automatically at the time battery voltage charging arrive 4.2V±0.05V.

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us