Premature baby incubator | infant warmer EKONBI13
MODEL / EKONBI13* Alarm functions for safety includes:Power failure, Temperature deviation, Temperature sensor failure , Over temperature.
- * A second thermal cut-out function for more safety
- Premature baby incubator EKONBI13 Safety Control Systems
- * Skin temperature sensor fall protect function avoid over temperature
Product Details
Quick Details
* Microprocessor based servo controlled temperature system
* Temperature displayed by LED
* Alarm functions:Power failure,Temperature deviation, Temperature sensor failure, Over temperature
* Skin temperature sensor failure
* A second thermal cut-out function for more safety
* Adopts anti-explosion micro crystal quartz infrared radiation tube
* Four transparent protector board
Specifications
Premature baby incubator EKONBI13 Brief introduction:
* Microprocessor based servo controlled temperature system
* Temperature displayed by LED
* Alarm functions:Power failure,Temperature deviation, Temperature sensor failure, Over temperature
* Skin temperature sensor failure
* A second thermal cut-out function for more safety
* Adopts anti-explosion micro crystal quartz infrared radiation tube
* Four transparent protector board

Premature baby incubator EKONBI13 Technical data
* Power supply: AC110/220V 60/50Hz
* Power input: 1000VA
* Operating condition
* Ambient Temperature:18℃-30℃
* Ambient Relative Humidity: 30%~75%RH
* Atmospheric Pressure: 700~1060 hPa
* Ambient Air Velocity: <0.3m/s
* Skin temperature control: 32℃~~38℃
* Skin temperature control accuracy: ≤0.5℃
* Mattress temperature uniformity: <2℃
* Skin temperature sensor accuracy: ± 0.3℃
* Warm-up time: ≤45min
* Mattress size: 67CM X54 CM
* Distance from heater to mattress: 80CM
Premature baby incubator EKONBI13 Safety Control Systems
* Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long
* Alarm functions for safety includes:Power failure, Temperature deviation, Temperature sensor failure, Over temperature.
* Temperature deviation can be amended in front panel directly
* A second thermal cut-out function for more safety
* Skin temperature sensor fall protect function avoid over temperature
Premature baby incubator EKONBI13 Standard configuration & Optional parts
Standard configuration:
Optional parts:
* Main body (including the Radiant source, Control system, Infant bed, Bracket); I.V.pole; Skin temperature sensor; Tray; Mattress; Castors; Transparent protector
* Drawer, RS-232(485) connector
Transport and storage
Premature baby incubator EKONBI13 Transport and storage:
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
Each unit is packed one case
Size:110CMX 78CM X 86CM
Gross weight: ≤90KG
Technical Specifications
Technical parameters from the currently available product information.
- * Alarm functions
- Power failure,Temperature deviation, Temperature sensor failure , Over temperature
- * Power supply
- AC110/220V 60/50Hz
- * Power input
- 1000VA
- * Ambient Temperature
- 18℃-30℃
- * Ambient Relative Humidity
- 30%~75%RH
- * Atmospheric Pressure
- 700~1060 hPa
- * Ambient Air Velocity
- <0.3m/s
- * Skin temperature control
- 32℃~~38℃
- * Skin temperature control accuracy
- ≤0.5℃
- * Mattress temperature uniformity
- <2℃
- * Skin temperature sensor accuracy
- ± 0.3℃
- * Warm-up time
- ≤45min
- * Mattress size
- 67CM X54 CM
- * Distance from heater to mattress
- 80CM
- * Alarm functions for safety includes
- Power failure, Temperature deviation, Temperature sensor failure , Over temperature.
- Environment Relative Humidity
- ≤95%
- Atmospheric Pressure
- 500~1060hPa
- Gross weight
- ≤90KG
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.