Incubators & Isolettes

Premature baby incubator | infant warmer EKONBI13

MODEL / EKONBI13

* Alarm functions for safety includes:Power failure, Temperature deviation, Temperature sensor failure , Over temperature.

  • * A second thermal cut-out function for more safety
  • Premature baby incubator EKONBI13 Safety Control Systems
  • * Skin temperature sensor fall protect function avoid over temperature
PRODUCT OVERVIEW

Product Details

Quick Details

* Microprocessor based servo controlled temperature system

* Temperature displayed by LED

* Alarm functions:Power failure,Temperature deviation, Temperature sensor failure, Over temperature

* Skin temperature sensor failure

* A second thermal cut-out function for more safety

* Adopts anti-explosion micro crystal quartz infrared radiation tube

* Four transparent protector board

Specifications

Premature baby incubator EKONBI13 Brief introduction:

* Microprocessor based servo controlled temperature system

* Temperature displayed by LED

* Alarm functions:Power failure,Temperature deviation, Temperature sensor failure, Over temperature

* Skin temperature sensor failure

* A second thermal cut-out function for more safety

* Adopts anti-explosion micro crystal quartz infrared radiation tube

* Four transparent protector board

infant warmer

Premature baby incubator EKONBI13 Technical data

* Power supply: AC110/220V 60/50Hz

* Power input: 1000VA

* Operating condition

* Ambient Temperature:18℃-30℃

* Ambient Relative Humidity: 30%~75%RH

* Atmospheric Pressure: 700~1060 hPa

* Ambient Air Velocity: <0.3m/s

* Skin temperature control: 32℃~~38℃

* Skin temperature control accuracy: ≤0.5℃

* Mattress temperature uniformity: <2℃

* Skin temperature sensor accuracy: ± 0.3℃

* Warm-up time: ≤45min

* Mattress size: 67CM X54 CM

* Distance from heater to mattress: 80CM

Premature baby incubator EKONBI13 Safety Control Systems

* Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long

* Alarm functions for safety includes:Power failure, Temperature deviation, Temperature sensor failure, Over temperature.

* Temperature deviation can be amended in front panel directly

* A second thermal cut-out function for more safety

* Skin temperature sensor fall protect function avoid over temperature

Premature baby incubator EKONBI13 Standard configuration & Optional parts

Standard configuration:

Optional parts:

* Main body (including the Radiant source, Control system, Infant bed, Bracket); I.V.pole; Skin temperature sensor; Tray; Mattress; Castors; Transparent protector

* Drawer, RS-232(485) connector

Transport and storage

Premature baby incubator EKONBI13 Transport and storage:

Environment Relative Humidity: ≤95%

Atmospheric Pressure: 500~1060hPa

Each unit is packed one case

Size:110CMX 78CM X 86CM

Gross weight: ≤90KG

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

* Alarm functions
Power failure,Temperature deviation, Temperature sensor failure , Over temperature
* Power supply
AC110/220V 60/50Hz
* Power input
1000VA
* Ambient Temperature
18℃-30℃
* Ambient Relative Humidity
30%~75%RH
* Atmospheric Pressure
700~1060 hPa
* Ambient Air Velocity
<0.3m/s
* Skin temperature control
32℃~~38℃
* Skin temperature control accuracy
≤0.5℃
* Mattress temperature uniformity
<2℃
* Skin temperature sensor accuracy
± 0.3℃
* Warm-up time
≤45min
* Mattress size
67CM X54 CM
* Distance from heater to mattress
80CM
* Alarm functions for safety includes
Power failure, Temperature deviation, Temperature sensor failure , Over temperature.
Environment Relative Humidity
≤95%
Atmospheric Pressure
500~1060hPa
Gross weight
≤90KG