Premature baby incubator | neonatal incubator EKONBI12
MODEL / EKONBI12Set temperature,air temperature,skin temperature and internal battery power are displayed by LED
- .Self-testing function,various failure alarms by audible and visual
- .The height od whole unit is adjustable
- .LED observe light,adjustable brightness
Product Details
Quick Details
Set temperature,air temperature,skin temperature and internal battery power are displayed by LED
Specifications
Transport Incubator EKONBI12
.Air mode and baby mode controlled by microcomputer
.Use AC Power and DC Power alternatively,DC 12V or DC 24V Power on the ambulance
.Set lemperature,air temperature,skin temperature and internal battery power are displayed by LED
.Self-testing function,various failure alarms by audible and visual
.Alarm function:
Power failure,Over temperature,Temperature deviation,Fan failure,Temperature sensor failure
.Double wall hood with side door and front door,4 operating windows and 2 iris ports,5 infusion seals
.The infant bed can be pulled out from side door easily
.Natural air flow humidity
.The height od whole unit is adjustable
.Oxygen supply system
.LED observe light,adjustable brightness
.Build-in storage cabinet

neonatal incubator EKONBI12 technical data
Powersupply: AC110/220V 60150Hz
Power input: 450VA
Environment temperature: 10℃- 30℃
Operating condition Environment relative humidity: 30%一75%
Environment air velocity of flow: <lm/s
Air temperature control range: 25℃一3TC 37.1℃一38'C
Skin temperature control range: 3YC一370C 37.1℃一38'C
AirlSkin temperature sensor accuracy: ±0.30C
Temperature fluctuation: ±1℃
Uniformity of mattress temperature: ±1.5℃
Air temperature deviation alarm: ±3℃
Skin temperature deviation alarm: ±1℃
warm-up time: ≤40min
Internal noise level: ≤60dB(A)
Main battery: DC12V 40AH,Li-ion battery
Charge time: 12hours
Battery use time: 2hours
Auxiliary battery: DC8.4V 0.17AH,Li-ion battery
Mattress size: 63cm(L)'32cm(W)
Trough capacity: 1200mL
Air filter: 0.5μm

neonatal incubator EKONBI12 transport and storage
Each unit is packed in two plywood cases (control unit): 100*70*88cm
N.W.:65Kg G.W.:11OKg
Trolley: 145'64'56cm
N.W.:30Kg G.W.:6OKg
Transport and storage
Environment temperature: 40C - +550C
Environment relative humidity: ≤95%
Atmospheric Pressure: 500一1060hpa
Technical Specifications
Technical parameters from the currently available product information.
- .Use AC Power and DC Power alternatively,DC
- 12V or DC 24V Power on the ambulance
- Powersupply
- AC110/220V 60150Hz
- Power input
- 450VA
- Environment temperature
- 10℃- 30℃
- Operating condition Environment relative humidity
- 30%一75%
- Environment air velocity of flow
- <lm/s
- Air temperature control range
- 25℃一3TC 37.1℃一38'C
- Skin temperature control range
- 3YC一370C 37.1℃一38'C
- AirlSkin temperature sensor accuracy
- ±0.30C
- Temperature fluctuation
- ±1℃
- Uniformity of mattress temperature
- ±1.5℃
- Air temperature deviation alarm
- ±3℃
- Skin temperature deviation alarm
- ±1℃
- warm-up time
- ≤40min
- Internal noise level
- ≤60dB(A)
- Main battery
- DC12V 40AH,Li-ion battery
- Charge time
- 12hours
- Battery use time
- 2hours