
Professional Full-Biochemistry,Auto-Chemistry Analysers CS-400
MODEL / CS-400Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, realizing supermicro volume detection of reaction solution.
- Automatic digital liquid level detection, stable performance, reducing probe surface contamination.
- New design reagent disk, less reagent consumption and more test items.
- Multiple function sample disk, original blood tube and multi-specification tubes compatible.
- LIS interface, supporting remote maintenance.
Product Details
Quick Details
Overall performance Equipment type: Fully automatic, discrete, STAT priority Throughput: 400T/H for photometry tests only; 600T/H for only ISE tests Test principle: Colorimetry, turbidimetries,ISE Analysis method: End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
Specifications
Features of Auto-Chemistry Analyzer CS-400:
Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, realizing supermicro volume detection of reaction solution. 60nm polished probe, liquid level detection and collision protection. Automatic digital liquid level detection, stable performance, reducing probe surface contamination. New design reagent disk, less reagent consumption and more test items. Multiple function sample disk, original blood tube and multi-specification tubes compatible. LIS interface, supporting remote maintenance. User defined combined batch input of patient information, application to fast setting for special hospital, blood station and physical examination.

Specification of Auto-Chemistry Analyzer CS-400:
1.Overall performance Equipment type: Fully automatic, discrete, STAT priority Throughput: 400T/H for photometry tests only; 600T/H for only ISE tests Test principle: Colorimetry, turbidimetries,ISE Analysis method: End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
2.Sample reagent unit Sample reagent position: 115sample positions, including 50 routine sample positions, 20 STAT position, 34 calibration positions, 8 QC positions, 3 detergent positions. Sample cuvettes specification: Standard cup, original blood tube, multi-specification tube available (Φ12~16)mm×(25~100)mm Sample volume: 2μl-35μl,0.1 stepping Sample reagent probe Liquid level detection and collision protection
3.Reaction unit Reagent probe: 2, with the function of liquid level detection and collision detection Reagent volume 20μl-350μl 1μl stepping Reaction cuvette 120 positions optical plastic cup Total volume of reaction liquid 150μl~450μ, Reaction temperature: 37 degree Reaction disk constant temperature: circulating water Mixer: Mix immediately after adding reagent Wastewater treatment with the function of concentrated waste liquid level alarming
4.Optical system Light source 20W/12V halogen lamps. Life is 2000hours Monochromator Grating photometry Photoelectron road rear spectrophotometry Wavelengths 340nm~800nm Detector Photodiode LED array
5.Calibration and QC Calibration method 1 point linear method, 2 point linear method, multiple point linear method, non-linear method Calibration tracking: Automatic description calibration K-value trends QC method: Real-time QC, daily QC and monthly QC Out of control processing: Alarming for out of control sample, record lost control reason

6.Operating system PC operating system Windows XP Analysis control software Graphical operating software English version Report printing Report formats support the user-defined mode, QC and state information etc. System connection TCP/IP network connection, standard RS-232C
7.Others Volume 1060mm×790mm×1150mm Weight 300kg Power supply Voltage AC 220V-22V, 50Hz, power 2kVA
Technical Specifications
Technical parameters from the currently available product information.
- Equipment type
- Fully automatic, discrete, STAT priority
- Throughput
- 400T/H for photometry tests only; 600T/H for only ISE tests
- Analysis method
- End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
- Sample reagent position
- 115sample positions, including 50 routine sample positions, 20 STAT position, 34 calibration positions, 8 QC positions, 3 detergent positions.
- Sample cuvettes specification
- Standard cup, original blood tube, multi-specification tube available (Φ12~16)mm×(25~100)mm
- Sample volume
- 2μl-35μl,0.1 stepping
- Reagent probe
- 2, with the function of liquid level detection and collision detection
- Reaction temperature
- 37 degree
- Reaction disk constant temperature
- circulating water
- Mixer
- Mix immediately after adding reagent
- Calibration tracking
- Automatic description calibration K-value trends
- Out of control processing
- Alarming for out of control sample, record lost control reason
- Power supply Voltage AC
- 220V-22V, 50Hz, power 2kVA
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.
