Lab Equipment > Biochemistry analyzer

Purchase High Quality Auto-Chemistry Analysers CS-600 from Medsinglong

MODEL / CS-600

Purchase High Quality Auto-Chemistry Analysers CS-600 from Medsinglong. Light source 20W/12V halogen lamps.

  • Equipment type Fully automatic ,discrete, STAT priority
  • Analysis method End-point, kinetics,fixed-time,etc.support single/double wavelength
  • Automatic rinsing for reaction cuvettes
  • Sample rerun and dilution function
PRODUCT OVERVIEW

Product Details

Quick Details

Overall performance Equipment type Fully automatic,discrete, STAT priority Throughput (Theoretical max) 600T/H for photometry tests only 600T/H for only ISE tests Test principle Colorimetry, turbidimetry, ISE Analysis method End-point, kinetics,fixed-time,etc.support single/double wavelength and 1-2 reagents item, linear and non-linear calibration Simultaneous analysis item 88 colorimetric items and 3 ISE items (K, Na, Cl optional)

Specifications

Features of Auto-Chemistry Analyzer CS-600:

Rear spectrophotometry of holographic concave flat field grating, Cluster - optical path, realizing supermicro volume detection of reaction solution 60 nm polished probe, liquid level detection, clot detection and collision protection Automatic rinsing for reaction cuvettes Sample rerun and dilution function English graphic operation software, supports various formats report printing supports User defined combined batch input of patient information, applicable to fast setting for special hospital, blood station and physical examination

Purchase High Quality Auto-Chemistry Analysers CS-600 from Medsinglong

Specification of Auto-Chemistry Analyzer CS-600:

1.Overall performance Equipment type Fully automatic,discrete, STAT priority Throughput (Theoretical max) 600T/H for photometry tests only 600T/H for only ISE tests Test principle Colorimetry, turbidimetry, ISE Analysis method End-point, kinetics,fixed-time,etc.support single/double wavelength and 1-2 reagents item, linear and non-linear calibration Simultaneous analysis item 88 colorimetric items and 3 ISE items (K, Na, Cl optional)

2.Sample unit Sample position 115 sample positions, including 50 routine sample positions, 20 STAT positions, 34 calibration positions, 8 QC positions, 3 detergent positions. Continuously cooling at calibration and QC positions to keep 5-15℃ within 24 hours Sample cuvettes specification Standard cup, original blood tube, multi-specification tube available(Φ12~16) mm ×(25~100)mm Sample barcode I2of5、code128、code39、UPC/EAN、code93 Sample volume 2μl~35μl,0.1μl stepping Sampling technology liquid level detection, clot detection and collision protection Sample probe carrying rate automatic warm water cleaning. Carrying rate≤0.1% Automatic sample dilution 3~170 times

3.Reagent unit Reagent probe 2, with the function of liquid level detection and collision Reagent volume 20μl~350μl, 1μl stepping Reagent position double reagent disk, 45X2, continuous 5-15℃ cooling within 24 hours, loading 70ml and 20ml standard reagent kit Reagent barcode code128 Reagent probe carrying rate automatic warm water cleaning. Carrying rate≤0.1%

4.Reaction unit Reaction cuvette 120 positions optical plastic cup, optical diameter is 6 mm Total volume of reaction liquid 150μl~450μl Reaction temperature 37℃,±0.1℃ Reaction disk constant temperature circulating water Mixing needle 2, after adding reagent, blending immediately Reaction cuvette cleaning 7 stops 11 steps by warm water rinsing Wastewater treatment two diffluence for high and low concentration waste water. With the function of waste liquid level alarming

5.Optical system Light source 20W/12V halogen lamps. Monochromator Grating photometry Photoelectron road Rear spectrophotometry Wavelength 340nm、380nm、405nm、450nm、480nm、505nm、546nm、 570nm、600nm、660nm、700nm、800nm Detector photodiode LED array OD linear range 0~3.3Abs

Purchase High Quality Auto-Chemistry Analysers CS-600 from Medsinglong

6.Operating system PC operating system Windows XP Analysis control software English version graphical operating software Main function of software automatic calibration, automatic barcode scanning, item compounding test, reagent info management, serum index, whole reaction process monitoring, dirty cup memory evading, prevent cross-contamination procedure, patient information memory and association input, automatic report audit, data multiple parameter query, report format statistic and printing, reference range classification, alarming information classification, user level classification, automatic dormancy and wake, real-time online help. Report printing report formats support the user-defined mode, QC and state information etc PC configuration CPU ≥2.2GHz(dual-core processor); Memory ≥1G; Harddisk ≥ 160G; 17 inch LCD display; Stylus, inkjet or laser printer (optional) System connection TCP/IP network connection, standard RS-232C

7.Others Volume 1060mm×790mm×1150mm Weight 300Kg Power supply voltage AC 220V / 230V, 50 / 60Hz, power 2KVA

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Reagent probe
2, with the function of liquid level detection and collision
Power supply voltage AC
220V / 230V, 50 / 60Hz, power 2KVA

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.