Safe Magnetic Resonance Imaging System EKONMRI08 for sale
MODEL / EKONMRI08Safe Magnetic Resonance Imaging System EKONMRI08 for sale. Practical advanced functional imaging.
- New generation fully digitalized and extensible multi-channel spectrometer
- Multichannel PA RF receiving coil with intelligent identifications
- High resolution conventional clinical images
- Practical advanced functional imaging.
Product Details
Quick Details
Type: Permanent magnet (NdFeB – Neodymium, Iron & Boron), eddy current free, open C type or 4-column type with self-temperature control Field strength: 0.4T±3% Passive shimming Field homogeneity: 40×40×38cm sphere ≤40ppm(Vpp 40×40×38cmsphere≤5ppm(Vrms) Vertical gap distance: 400mm±20mm
Specifications
Features of OPER-0.4 Open Permanent Magnet MRI system EKONMRI08:
New generation fully digitalized and extensible multi-channel spectrometer; Powerful high efficiency and high-fidelity gradient system; Multichannel PA RF receiving coil with intelligent identifications; English operating system and high extensible computer system; High resolution conventional clinical images; Practical advanced functional imaging.

Specification of OPER-0.4 Open Permanent Magnet MRI system EKONMRI08:
Magnet: Type: Permanent magnet (NdFeB – Neodymium, Iron & Boron), eddy current free, open C type or 4-column type with self-temperature control Field strength: 0.4T±3% Passive shimming Field homogeneity: 40×40×38cm sphere ≤40ppm(Vpp 40×40×38cmsphere≤5ppm(Vrms) Vertical gap distance: 400mm±20mm
Gradient system: Gradient amplifier: US imported product Field strength: 24mT/m effective 40.8mT/m Slew rate: single axis ≤80mT/m/ms effective ≤136mT/m/ms Linearity: 40cm*40cm*38cm ellipsoid<5% Cooling system: gradient power – wind cooling Gradient coil – no cooling system required
RF transmitting & receiving system: Type of transmitter & receiver: Digital (US imported product) Receiving channels: multiple channels Frequency range: DC-22MHZ Maximum receiver bandwidth: 1.25MHZ Pre-amplifier gain max: 30dB Noise figure: 0.3dB RF amplifier: ≥6kw (17.00MHz) (US imported product) RF transmitting coil: panel transmitting coil RF receiving coil: multiple channel coil
Auto pre-scan function: Auto RF correction Auto frequency lock Auto gain adjusting Auto coil identification Auto coil tuning Automatic shimming linear compensation
Standard Configuration of OPER-0.4 Open Permanent Magnet MRI system EKONMRI08:

Magnet: Permanent magnet (0.4T) (NdFeB) Self-temperature control system Self-temperature control system power and control unit
RF transmitting & receiving system: Digital transmitting and receiving system (USA and UK imported products) RF amplifier (USA imported) panel transmitting coil Pre-position amplifier Phase Array RF Receiving coils: Head, Body (big), Body (small), Neck, Knee, Breast and Wrist coil each
Gradient System: Gradient amplifier and power supply (USA imported) X Y Z gradient coil
Spectrometer: Multi-channel digital spectrometer (UK imported)
Computer System: Imaging workstation 2nd generation Intel Core ™ (≥3.3GHz) Graphics memory: 1GB Memory: 4GB Hard driver: 500GB Removable storage: DVD+RW double burn 21” TFT monitor with at least 1280x1024 resolution Post processing image software
Patient System: Table Intercom system Background music system
Technical Specifications
Technical parameters from the currently available product information.
- Type
- Permanent magnet (NdFeB – Neodymium, Iron & Boron), eddy current free, open C type or 4-column type with self-temperature control
- Field strength
- 0.4T±3% Passive shimming
- Field homogeneity
- 40×40×38cm sphere ≤40ppm(Vpp 40×40×38cmsphere≤5ppm(Vrms)
- Vertical gap distance
- 400mm±20mm
- Gradient amplifier
- US imported product Field strength: 24mT/m effective 40.8mT/m Slew rate: single axis ≤80mT/m/ms
- effective ≤136mT/m/ms Linearity
- 40cm*40cm*38cm ellipsoid<5%
- Type of transmitter & receiver
- Digital (US imported product) Receiving channels: multiple channels
- Frequency range
- DC-22MHZ
- Maximum receiver bandwidth
- 1.25MHZ Pre-amplifier gain max: 30dB
- Noise figure
- 0.3dB
- RF amplifier
- ≥6kw (17.00MHz) (US imported product) RF transmitting coil: panel transmitting coil
- Phase Array RF Receiving coils
- Head, Body (big), Body (small), Neck, Knee, Breast and Wrist coil each
- nd generation Intel Core ™ (≥3.3GHz) Graphics memory
- 1GB
- Memory
- 4GB
- Hard driver
- 500GB
- Removable storage
- DVD+RW double burn