Ultrasound > Fetal Doppler

Top Fetal Doppler EKONJB08 for sale | Medsinglong

MODEL / EKONJB08

Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB

PRODUCT OVERVIEW

Product Details

Quick Details

Safety: Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266 Ultrasonic emitting frequency: 3MHz Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB Spatial-peak temporal-peak acoustic pressure: ≤1MPa Output power: <20mW

Specifications

Features of Fetal Doppler EKONJB08:

High sensitive ultrasound probe Detect the heart rates of 16th week fetus Record the fetal heart beat by computer

Top Fetal Doppler EKONJB08 for sale | Medsinglong
Top Fetal Doppler EKONJB08 for sale | Medsinglong

Specifications of Fetal Doppler EKONJB08:

Safety: Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266 Ultrasonic emitting frequency: 3MHz Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB Spatial-peak temporal-peak acoustic pressure: ≤1MPa Output power: <20mW Effective area of the ultrasonic transducer active element:2.65cm2±0.3cm2 The acoustic coupling medium for normal use: ph: 5.5~8, Acoustic impedance: ≤1.7*105g /cm2·s Working mode: Continuous wave Doppler Audio output: Audio output power: <0.5 W Audio out Socket: Φ3.5mm/USB interface Stand-by Time: >4hours Suitable gestation: 16 gestational weeks or later, difference in pregnant mater. Physical Characteristic: Size: 104.5mm(length) * 50mm(width) * 70mm(height) Weight: 69.5g (only main unit, not including battery)

Top Fetal Doppler EKONJB08 for sale | Medsinglong
Top Fetal Doppler EKONJB08 for sale | Medsinglong

Medial & Video of Fetal Doppler EKONJB08

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Safety
Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266
Ultrasonic emitting frequency
3MHz
Spatial-peak temporal-peak acoustic pressure
≤1MPa
Output power
<20mW
Effective area of the ultrasonic transducer active element
2.65cm2±0.3cm2
The acoustic coupling medium for normal use
ph: 5.5~8, Acoustic impedance: ≤1.7*105g /cm2·s
Working mode
Continuous wave Doppler
Audio output power
<0.5 W
Audio out Socket
Φ3.5mm/USB interface
Stand-by Time
>4hours
Suitable gestation
16 gestational weeks or later, difference in pregnant mater.

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us