Vet equipment > Vet anesthesia equipment

Veterinary Anesthesia Ventilator EKONBC268| Medsinglong

MODEL / EKONBC268

Veterinary Anesthesia Ventilator EKONBC268| Medsinglong. 2,Light and easy to move,save animal hospital cost.

  • Compact and salve the space
  • Light and easy to move
  • 1,Compact and salve the space.
  • 2,Light and easy to move,save animal hospital cost.
PRODUCT OVERVIEW

Product Details

Quick Details

Compact and salve the space Light and easy to move With breathing mode PCV mode With big animal bellow and small animal bellow The gas source pipeline take the high precious gas source HD TFT Touch screen touch at key to Set parameter Matching with different brand veterinary anesthesia machine

Specifications

Anesthesia Ventilator

Basic description Parameter Description Display 9 inch TFT, with touch screen. Drive gas Gas type O2 or Air Inlet pressure 280-600 kPa. Max flow ≤ 120 L / min. Operating Mode VCV,PCV,SPONT,Manual,Demo Waveform Waveform: Pressure,Flow-rate,Volume Loop:PV loop, PF loop,FV loop Safety Pressure System pressure does not exceed 6 KPa. Battery Type Li-ion,work time more than 2 hours Parameters setting range

Parameter description Tidal volume Range: 20 - 1500ml; Increment: 1 mL; Respiratory rate Range: 1 ~ 100 bpm; Inspiratory time Range: 0.1 ~ 10.0 s Respiratory ratio Range: 9.9:1 to 1:9.9 Percentage of inspiratory pause Range: 0 to 50% PEEP Range: OFF, 3 ~ 20 cmH2O Pressure Support Range: 0 ~ 60 cmH2O Pressure Control Range: 5 ~ 60 cmH2O Flow trigger Range: 0.5 ~ 20L/min Pressure Trigger Range: -1 ~ -20 cmH2O PSV Insp Termination Level 25%. Monitored parameters Parameter Description Inspiratory tidal volume Range: 0 ~ 2500 mL Expiratory tidal volume Range: 0 ~ 2500 mL Minute ventilation Range: 0 ~ 60 L / min Spontaneous minute ventilation Range: 0 ~ 60 L / min Respiratory rate Range: 0 ~ 100 bpm Spontaneous breathing frequency Range: 0 ~ 100 bpm Respiratory ratio Range: 9.9:1 to 1:9.9 Peak airway pressure Range: 0 ~ 100 cmH2O Mean airway pressure Range: 0 ~ 100 cmH2O PEEP Range: 0 ~ 100 cmH2O Inspiratory plateau pressure Range: 0 ~ 100 cmH2O FiO2(optional) Range: 15 to 100% Alarm settings

Alarm type Range Tidal volume High 0 ~ 2000 mL, OFF Low 0 ~ 1500 mL Minute ventilation High 1 ~ 99 L Low 0 ~ 98 L Respiratory rate High 1 ~ 100bpm Low 0 ~ 99 bpm FiO2(optional) High 19 ~ 100% Low 18 ~ 99% Airway pressure High 6 ~ 99 cmH2O Low 0 ~ 9 8 cmH2O FiCO2 (optional) High 0.1 to 13.3%; Low 0 to 13.2% Continuous Positive Airway Pressure Airway pressure greater than (PEEP +15) cmH2O, 15 s sustained when an alarm is triggered. Negative pressure alarm Airway pressure is less than (-10) cmH 2 O. Apnea alarm Setting time is 10 ~ 60 s, in increments of 1 s. Gas deficiency alarm Gas pressure is less than 280 kPa. AC power failure alarm The mains breaks down or the power cord disconnects Low battery alarm Alarm battery time is 20 min. Alarm battery is exhausted Alarm battery time is 10 min. Silent Alarm ≤ 120 s O2 sensor failure FIO2 <15% Vol

Veterinary Anesthesia Ventilator EKONBC268| Medsinglong
Veterinary Anesthesia Ventilator EKONBC268| Medsinglong
Veterinary Anesthesia Ventilator EKONBC268| Medsinglong
Veterinary Anesthesia Ventilator EKONBC268| Medsinglong
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Display
9 inch TFT, with touch screen.
Inlet pressure
280-600 kPa.
Max flow ≤
120 L / min.
Safety Pressure System pressure does not exceed
6 KPa.
Battery Type Li-ion,work time more than
2 hours
Tidal volume Range
20 - 1500ml; Increment: 1 mL
Respiratory rate Range
1 ~ 100 bpm
Inspiratory time Range
0.1 ~ 10.0 s
Respiratory ratio Range
9.9:1 to 1:9.9
Percentage of inspiratory pause Range
0 to 50%
PEEP Range
OFF, 3 ~ 20 cmH2O
Pressure Support Range
0 ~ 60 cmH2O
Pressure Control Range
5 ~ 60 cmH2O
Flow trigger Range
0.5 ~ 20L/min
Pressure Trigger Range
-1 ~ -20 cmH2O
Inspiratory tidal volume Range
0 ~ 2500 mL
Expiratory tidal volume Range
0 ~ 2500 mL
Minute ventilation Range
0 ~ 60 L / min

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us