X rays

X-ray High voltage generator machine EKONDR09

MODEL / EKONDR09

Wireless flat panel detector is free from cable andmakes position more flexible; Can achieve fullcircle rotation, easy movement; New folding stand design.

  • Wireless flat panel detector is free from cable andmakes position more flexible
  • Can achieve fullcircle rotation, easy movement
  • New folding stand design
  • Mobile digital X-ray High voltage generator machine EKONDR09 Technical Specification
PRODUCT OVERVIEW

Product Details

Quick Details

40kW High power & high voltage generator and large heat capacity of X-ray tube

Wireless flat panel detector is free from cable andmakes position more flexible

Can achieve fullcircle rotation, easy movement

New folding stand design

Dual power supply

dynamic lithium battery

Specifications

Mobile digital X-ray High voltage generator machine EKONDR09

  • 40kW High power & high voltage generator and large heat capacity of X-ray tube
  • Wireless flat panel detector is free from cable andmakes position more flexible
  • Can achieve fullcircle rotation, easy movement
  • New folding stand design
  • Dual power supply
  • dynamic lithium battery
X-ray High voltage generator machine EKONDR09

Mobile digital X-ray High voltage generator machine EKONDR09 Technical Specification:

·X- ray High voltage generator ·Standard output power:40kW ·mA range:10-400mA ·Tube voltage range:40-150kV ·mAs range :0.1-250mAs ·Load time range:0.001s~6.3s ·Input voltage:450VDC/48VDC±10% ·High voltage output master frequency:50kHz±5% ·High voltage transformer structure:The power frequency ·X-ray tube ( 配置1) E7843 ·Focus range:0.6/1.2mm ·Anode heat capacity :150kHu ·Anode types: rotating anode, maximum speed: 3200 revolutions per minute ·Pipe sleeve heat capacity: 1250kHu ·The maximum voltage:150kV ·The anode input power:Big focus:50kW,Small focus:22kW ·Anode angle 12° ·The inherent filtration:1.3mm Al/75kV ·Collimator ·The inherent filtration:1.0 mm Al /75 kV; ·Collimator is equipped with LED lights(Bright 30S are automatically extinguished) ·Collimator is built into measuring ruler ·The tube bracket structure ·X-ray tube support way: Folding arm ·Tube focus distance to the ground:507㎜~2000㎜,±5% ·Arm’s Folding Range:±60° ·Tube Tilting Angle:±90° ·Tube Vertical Rotation Angle:-30°~+90° ·Collimator axial rotation :±360° ·Detector ·Detector:Mars1417V-PSI ·WIFI connection ,Amorphous Silicon,whole panel technology ·Detector valid exposure size :356×432mm ·Pixel size:150 µm ·The effective camera size of the detector:14×17inch ·Gathering matrix:2560×3072 ·Spatial resolution≥3.4 lp/mm ·Pixel gray level:14bit ·Detector cooling mode: natural cooling

X-ray High voltage generator machine EKONDR09

Mobile digital X-ray High voltage generator machine EKONDR09 Image Specification:

·Digital image workstation ·CPU frequency:CORE i3 ·Memory capacity:4GB ·Hard drive capacity :500 GB ·Display size: 17 inch LCD touch screen ·Display screen Maximum resolution≥1280×1024; ·64 bit Windows operation system ·Image acquisition software ·Patient registration: acquisition, find the patient data, to prepare for the photography ·Radio graphic examination:setting system parameters, exposure photography and get the image ·Images display, image analysis, processing and output ·Data management: managing patient data, leading in, leading out, batch file, etc in accordance with DICOM3.0 ·Configure calibration: the system components such as flat-panel detector, such as tube for automatic configuration and calibration ·System diagnosis: monitoring system status, diagnosis of the system fault

X-ray High voltage generator machine EKONDR09

Mobile digital X-ray High voltage generator machine EKONDR09 Power Specification:

X-ray High voltage generator machine EKONDR09
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

·Standard output power
40kW
·mA range
10-400mA
·Tube voltage range
40-150kV
·mAs range
0.1-250mAs
·Load time range
0.001s~6.3s
·Input voltage
450VDC/48VDC±10%
·High voltage output master frequency
50kHz±5%
·High voltage transformer structure
The power frequency
·Focus range
0.6/1.2mm
·Anode heat capacity
150kHu
·Anode types
rotating anode, maximum speed: 3200 revolutions per minute
·Pipe sleeve heat capacity
1250kHu
·The maximum voltage
150kV
·The anode input power
Big focus:50kW ,Small focus:22kW
·The inherent filtration
1.3mm Al/75kV
·X-ray tube support way
Folding arm
·Tube focus distance to the ground
507㎜~2000㎜,±5%
·Arm’s Folding Range
±60°